background image

25

103546

PARTS

CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support
our customer’s needs by providing original replacement parts and accessories.

MANUAL SHUTOFF
VALVE - GA5010

Manual shutoff valve with 1/8"
NPT tap.

Baltimore Electric
1348 Dixwell Avenue
Hamden, CT 06514
1-800-397-7553
203-248-7553
Parts Department

Portable Heater Parts
342 N. County Rd. 400 East
Valparaiso, IN 46383
All States
219-462-7441
1-800-362-6951

FBD
1349 Adams Street
Bowling Green, KY 42103
502-846-1199
1-800-654-8534

Four Flags Power
Products
1115 Stateline Road
Niles, MI 49120
616-684-2697
1-800-268-4983
Parts Only

Master Service Center

Dayton Hardware
P.O. Box 275
North Dayton Station
Dayton, OH 45404
All States
513-258-3721
OH 1-800-762-3426

Halco Enterprises
208 Carter Drive, Unit 21
West Chester, PA 19382
215-696-2670
1-800-368-0803

LA Porte’s Parts & Service
2444 North 5th Street
Hartsville, SC 29550
803-332-0191
Parts Department

Cans Unlimited, Inc.
P.O. Box 645
Taylor, SC 29687
All States
803-879-3009
1-800-845-5301

1184 Wilson NW
Walker, MI 49504
616-791-4760
1-800-446-1446

Washer Equipment Co.
1715 Main Street
Kansas City, MO 64108
KS, MO, AR
816-842-3911

East Coast Energy
Products
707 Broadway
W. Long Branch, NJ
07764
908-870-8809
1-800-755-8809

Tarantin Tank Co.
P.O. Box 6129
Freehold, NJ 07728
908-780-9340
1-800-922-0724

SERVICE

PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this
manual. Send a check for $5.00 payable to DESA International.

ACCESSORY

Purchase this heater accessory from your local dealer. If they cannot supply this
accessory, either contact your nearest Parts Central (see above) or call DESA
International’s Parts Department at 1-800-972-7879 for referral information. You
can also write to the address listed on the back page of this manual.

Summary of Contents for Comfort Glow CGN10L

Page 1: ...mmediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perform...

Page 2: ...losion and carbon monoxide poisoning WARNING ICON G 001 DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with head...

Page 3: ...ter if not enough fresh air is available See Fresh Air for Combus tion and Ventilation pages 5 through 8 6 Keep all air openings in front and bottom of heater clear and free of debris This will insure...

Page 4: ...gnitor Button 1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you...

Page 5: ...ction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air...

Page 6: ...d gas heater ___________________ Btu Hr Gas fireplace logs ___________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Example Gas water heater 44 000 B...

Page 7: ...Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one wi...

Page 8: ...ra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or sp...

Page 9: ...0 If you can provide greater clearances from floor ceiling and joining wall WARNING ICON G 001 CAUTION If you install the heater in a home garage heater pilot and burner must be at least 18 inches abo...

Page 10: ...R JOINING WALL WARNING ICON G 001 WARNING Maintain minimum clearances shown in Figure 5 If you can provide greater clearances from floor and joining wall INSTALLINGTO WALL Continued For convenience an...

Page 11: ...Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill at least 1 1 4 deep 2 Fold wall anchor see Figure 6 3 Insert wall anchor wings first into hole Tap anchor...

Page 12: ...near bottom on back panel of heater see Figure 11 2 Mark screw location on wall 3 Remove heater from wall 4 If installing bottom mounting screw into hollow or solid wall install wall anchor Follow st...

Page 13: ...valves Install sediment trap in supply line as shown in Figure 12 page 14 Locate sediment trap where it is within reach for cleaning Locate sediment trap where trapped matter is not likely to freeze...

Page 14: ...gas piping and connections for leaks after installing or servicing Correct all leaks at once 3 Minimum Manual Shutoff Valve From Gas Meter 4 W C to 10 5 W C Pressure CONNECTING TO GAS SUPPLY Continued...

Page 15: ...RE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 13 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joi...

Page 16: ...rn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in...

Page 17: ...ass panel If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 20 through 23 Also contact a qualified service person or gas supplier...

Page 18: ...t is lit After 30 seconds release control knob 5 Replace front panel OPERATING HEATER Continued Check pilot flame pattern and burner flame pattern often PILOT FLAME PATTERN Figure 17 shows a correct p...

Page 19: ...than 1 2 the glass panel height INSPECTING BURNER Continued WARNING ICON G 001 WARNING If yellow tipping occurs your heater could produce increased levels of carbon monoxide If burner flame pattern s...

Page 20: ...it WARNING ICON G 001 CAUTION You must keep control areas burner and circulating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualifi...

Page 21: ...ausing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple dam aged 7 Control valve damaged REME...

Page 22: ...eater blocked 4 Dirty or partially clogged burner orifice REMEDY 1 Clean burner orifice see Cleaning and Mainte nance page 20 or replace burner orifice 2 Replace burner orifice 3 Contact local natural...

Page 23: ...nnections page 14 1 Refer to Fresh Air for Combustion and Venti lation requirements page 5 OBSERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produce...

Page 24: ...l s Technical Service Department at 1 800 323 5190 for referral information When contacting your dealer or DESA International have ready your name your address model number of your heater how heater w...

Page 25: ...ter PA 19382 215 696 2670 1 800 368 0803 LA Porte s Parts Service 2444 North 5th Street Hartsville SC 29550 803 332 0191 Parts Department Cans Unlimited Inc P O Box 645 Taylor SC 29687 All States 803...

Page 26: ...26 103546 HEATER EXPLODED VIEW 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 23 24 27 22 26 25 19 20 28 29 CGN10L CGN6L...

Page 27: ...ssembly 1 12 1 098514 01 098514 01 Thermocouple 1 12 2 098594 01 098594 01 Ignitor Electrode 1 13 099386 02 099386 02 Burner 1 14 099387 05 099387 05 Pilot Tubing 1 15 098251 01 098251 03 Injector 1 1...

Page 28: ...oes not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects cau...

Reviews: