102653

INSTALLING

Continued

 WARNING

Failure to position the parts in accordance with these diagrams or failure
to use only parts specifically approved with this heater may result in
property damage or personal injury.

INSTALLING LOGS (Split Oak Design Models)

Bottom Middle Log (#2)

Metal Post

Metal Post

Peg

Groove

Groove

Grate

Each log is marked with a number. These numbers will help you identify the log when
installing. It is very important to install these logs exactly as instructed. Do not modify
logs. Only use logs supplied with heater.

1. Place front logs (#1L and #1R) on top of the grate. Make sure the notches in the bottom

of the logs fit over the grate prongs (see Figure 22). Push back of logs flush with metal
grate bar.  

Note:

 

18" model has only one front log.

2. Rest bottom middle log (#2) behind metal posts on front burner. Make sure the grooves in

the bottom of the log fit over the grate. Bring the log forward next to the metal posts. The
pegs on the log must be on top (see Figure 23).

3. Slide the grooves in the back of the rear log (#3) against the rear grate prongs. Make

sure the peg on the log is on top (see Figure 24).

4. Place the top middle log (#4) on the bottom middle log (#2). Make sure the pegs of the

bottom middle log fit securely in the holes of the top middle log (see Figure 25).

Figure 22 - Installing Front Logs

(#1L and #1R)

Grate
Prongs

Metal Grate Bar

Front Log (#1L)

Notch

Front Log (#1R)

Figure 23 - Installing Bottom

Middle Log (#2)

Rear Log (#3)

Peg

Grate
Prong

Grate
Prong

Rear
Burner

Groove
in Back
of Log

Groove
in Back
of Log

Figure 24 - Installing Rear Log (#3)

Top Middle Log (#4)

Hole

Peg

Peg

Bottom
Middle Log

Figure 25 - Installing Top Log (#4)

Continued

Hole

Summary of Contents for CF18PV

Page 1: ...plier call the fire department Installation and service must be per formed by a qualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service ormain...

Page 2: ...is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and understand all Warnings Keep...

Page 3: ...ied service person Note During initial operation slight smoking may occur due to log curing and heater burning manufacturing residues 10 Do not allow fans to blow directly into the fireplace Avoid any...

Page 4: ...ar Log Base Assembly Front Burner Piezo Ignitor Rear Burner Crossover Log Top Middle Log Bottom Middle Log Figure 2 Standard Oak Design Model Control Knob Right Front Branch Base Assembly Front Log Re...

Page 5: ...Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if there is n...

Page 6: ...s around window and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings If your home...

Page 7: ...er ___________________ Btu Hr Gas fireplace logs ___________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Example Gas water heater 40 000 Btu Hr Vent...

Page 8: ...of ventilation grills or ducts WARNING ICON G 001 WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in...

Page 9: ...thing or other flammable objects are less than 36 inches from the front top or sides of the heater in high traffic areas in windy or drafty areas WARNING ICON G 001 CAUTION This heater creates warm ai...

Page 10: ...8 17 14 20 14 24 17 14 26 18 30 17 14 32 22 MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size Side Wall Ceiling Floor 18 24 30 16 42 5 Carefully follow the instructions below This will ens...

Page 11: ...behind it Non combustible material must extend at least 8 up for all models If non combus tible material is less than 12 you must install the fireplace hood accessory 24 and 30 models only See chart...

Page 12: ...accessory to deflect heat away from your mantel shelf See chart below and Figures 7 and 8 for minimum clearances IMPORTANT If you cannot meet these minimum clearances you must operate heater with chim...

Page 13: ...you must maintain the minimum distance of 14 to combustibles see Figure 9 Figure 9 Minimum Fireplace Clearances If Installed at Floor Level B If combustible materials are less than 14 to the fireplac...

Page 14: ...number 1 or 2 above apply to you you must permanently open chimney flue damper You must install the damper clamp accessory to order see Accessories page 35 This will insure vented operation see Figur...

Page 15: ...s in thermostat bulb wire Keep thermostat bulb in mounting bracket Installation Items Needed hardware package provided with heater approved flexible gas hose not provided if allowed by local codes sea...

Page 16: ...ll the external regulator between the heater and propane supply Installation Items Needed Before installing heater make sure you have the items listed below external regulator supplied by installer se...

Page 17: ...hook up NPT tap must be upstream from heater see Figure 15 page 18 Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could...

Page 18: ...esting gas Supply Piping system Test Pressures In Excess Of 1 2 PSIG 1 Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will dama...

Page 19: ...forming show a leak 4 Correct all leaks at once Pressure Testing Heater Gas Connections 1 Open manual shutoff valve see Figure 16 2 Open propane supply tank valve 3 Make sure control knob of heater i...

Page 20: ...see Figure 18 2 Slide front log 2 into place behind front burner Make sure tabs at bottom of log are behind front burner see Figure 19 3 Place crossover log 3 into place see Figure 20 Be sure to plac...

Page 21: ...Note 18 model has only one front log 2 Rest bottom middle log 2 behind metal posts on front burner Make sure the grooves in the bottom of the log fit over the grate Bring the log forward next to the...

Page 22: ...all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance...

Page 23: ...After 30 seconds release control knob If control knob does not pop out when released contact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 3 through 7 Thi...

Page 24: ...ease control knob Now follow step 8 above Thermocouple Figure 28 Pilot Ignitor Electrode Pilot Burner 8 Turn control knob counterclockwise C clockwise to desired heating level The burners should light...

Page 25: ...ents at the bottom you must open the vents before operating heater You must operate this heater with a fireplace screen in place Make sure fireplace screen is closed before running heater 1 STOP Read...

Page 26: ...his results in increased heating comfort 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop out when released contact...

Page 27: ...ater could produce increased levels of carbon monoxide If front burner flame pattern shows yellow tipping followinstructionsatbottomofthispage Yellowflameonrear burner is normal FRONT BURNER FLAME PAT...

Page 28: ...or similar object to clean ODS pilot This can damage ODS pilot unit POSSIBLE CAUSE 1 Ignitor electrode not connected to ignitor cable 2 Ignitor cable pinched or wet 3 Piezo ignitor nut is loose 4 Brok...

Page 29: ...4 turn more 7 Replace thermocouple 8 Replace control valve OBSERVED PROBLEM When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control...

Page 30: ...8 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Have gas l...

Page 31: ...l valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Thermostat sensing bulb needs to be repositioned REMEDY 1 This is common with most...

Page 32: ...t Sensing Bulb 1 Locate the gas valve assembly and thermostat sensing bulb see Figure 35 2 The adhesive backed mounting clip see Figure 36 is attached to the thermostat sensing bulb Remove the adhesiv...

Page 33: ...ve backed Mounting Clip Glass Doors Figure 40 Installing Thermostat Sensing Bulb behind Glass Doors Thermostat Sensing Bulb 5 The mounting clip must be a minimum of 3 from bottom of fireplace to preve...

Page 34: ...SPECIFICATIONS 18 Variable 24 Variable 30 Variable Manually Manually Manually Controlled Controlled Controlled Btu Variable 16 000 26 000 20 000 33 000 21 500 36 000 Type Gas Propane Only Propane Onl...

Page 35: ...Parts Department at 1 800 972 7879 for referral information When calling DESA International have ready model number of your heater the replacement part number ACCESSORIES Purchase these heater accesso...

Page 36: ...RATED PARTS BREAK DOWN Variable Manually Controlled Models 18 20 19 26 25 21 21 27 28 6 7 8 29 29 25 10 9 11 12 13 15 22 23 27 1 27 2 24 7 1 7 2 14 16 17 4 5 3 2 1L 1R VS18PV CFS18PV VS24PVA CFS24PVA...

Page 37: ...867 10 098867 10 Gas Regulator 1 13 M11084 38 M11084 38 M11084 38 Screw 2 14 101011 01 101011 02 101011 03 Inlet Tube 1 15 098354 01 098354 01 098354 01 Control Knob 1 16 098462 03 098462 03 098462 03...

Page 38: ...TRATED PARTS BREAK DOWN Thermostat Controlled Models 31 6 25 6 7 8 9 10 11 8 8 29 13 12 13 14 15 16 18 17 19 24 26 27 7 1 7 2 29 22 23 21 28 20 30 3 1 2 4 5 10 1 10 2 VL18PTA CF18PTA VL24PTA CF24PTA V...

Page 39: ...ecals 1 13 098271 07 098271 06 098271 06 Ignitor Cable 1 14 102445 01 102445 01 102445 01 Piezo Ignitor 1 15 098867 10 098867 10 098867 10 Gas Regulator 1 16 M11084 38 M11084 38 M11084 38 Screw 2 17 1...

Page 40: ...6 7 8 9 10 11 8 8 29 13 12 13 14 15 16 18 17 19 24 26 27 7 1 7 2 29 22 23 21 28 20 30 10 1 10 2 4 5 3 2 1R 1L ILLUSTRATED PARTS BREAK DOWN Thermostat Controlled Models VS18PTA CFS18PTA VS24PTA CFS24PT...

Page 41: ...Base Assembly with decals 1 13 098271 07 098271 06 098271 06 Ignitor Cable 1 14 102445 01 102445 01 102445 01 Piezo Ignitor 1 15 098867 10 098867 10 098867 10 Gas Regulator 1 16 M11084 38 M11084 38 M1...

Page 42: ..._________________________________________ _________________________________________________________________ _________________________________________________________________ __________________________...

Page 43: ..._________________________________________ _________________________________________________________________ _________________________________________________________________ __________________________...

Page 44: ...instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse...

Reviews: