19
102653
ON
POSITION
OFF
POSITION
3. Pressurize supply piping system by either using compressed air or
opening propane supply tank valve.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to
gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Re-connect heater and manual shutoff valve to gas supply. Check re-connected fittings
for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (see Figure 16).
2. Pressurize supply piping system by either using compressed air or opening propane
supply tank valve.
3. Check all joints from propane supply tank to manual shutoff valve (see Figure 16).
Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Pressure Testing Heater Gas Connections
1. Open manual shutoff valve (see Figure 16).
2. Open propane supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve (thermostat-
controlled models) or control valve (manually-controlled models) (see Figure 16).
Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 22 through 26). Check all other internal
joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 24 [thermostat-
controlled models] or page 26 [manually-controlled models]).
INSTALLING
Continued
Figure 16 - Manual Shutoff Valve
Open
Closed
Manual
Shutoff
Valve
Figure 17 - Checking Gas Joints
Thermostat Gas Valve or
Control Valve Location
Propane
Supply Tank
Manual
Shutoff
Valve
Continued