SPECIFICATIONS
Output Rating (BTU/Hr)
High ...................................................... 50,000
Medium ................................................ 40,000
Low ...................................................... 30,000
Fuel ............................................................ Propane Vapor Only
Fuel Consumption
Gallons/Hour ........................................ 2.19 / 1.09
Pounds/Hour ......................................... 9.28 / 4.64
Supply Pressure To Regulator
Minimum (for input adjustment) .......... 10 psi
Maximum ............................................. 200 psi
Regulator Outlet Pressure
High ...................................................... 18" WC
Manifold Pressure
High ...................................................... 13.7" WC
Low ...................................................... 17" WC
Hot Air Output (CFM Approx) ................. 275
Motor ......................................................... 3,300 RPM, 1/20 HP
Electric Input ............................................. 120 volt/60 hertz
Amperage .................................................. 2
Ignition ...................................................... Manual, Piezo
Ignitor Gap ................................................. 0.17"
Temperature Range for Operation* ........... -20°F to 85°F *
Heater Weight (Pounds) ............................ 13
Shipping Weight ........................................ 15
Size - L x W x H (Inches)
Heater ................................................... 18.5 x 8.0 x 12.8
Carton ................................................... 19.4 x 9.75 x 14.75
* When running heater in temperatures above 85° F, high internal
temperatures may cause thermal limit device to shut down heater.
Parts Under Warranty
Contact authorized dealers of this product. If they can’t supply
original replacement part(s), either contact your nearest authorized
service center or call DESA International’s Technical Service
Department at 1-866-672-6040.
When calling DESA International, have ready
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• purchase date
In most cases, we will ask you to return the part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they can’t supply
original replacement part(s), either contact your nearest Parts Cen-
tral or call DESA International at 1-866-672-6040 for referral
information.
When calling DESA International, have ready
• model number of your heater
• the replacement part number
REPLACEMENT PARTS
WARNING: Use only original replacement parts.
This heater must use design-specific parts. Do not
substitute or use generic parts. Improper replace-
ment parts could cause serious or fatal injuries. This
will also protect your warranty coverage for parts
replaced under warranty.
ACCESSORIES
Purchase accessories and parts from your nearest dealer or service
center. If they can not supply an accessory or part, either contact
your nearest Parts Central (listed in the separate Authorized Service
Center booklet) or contact DESA International for information.
DESA International
P.O. Box 90004
Bowling Green, KY
42102-9004
1-866-672-6040
Part Number
Description
LPA3055
Hose/Regulator Assembly
U.L. listed.
LPA4020
Fuel Gas Connector
Connects regulator to all standard propane
tanks. U.L. and A.G.A. listed.
SPECIFICATIONS
ACCESSORIES
REPLACEMENT PARTS
TECHNICAL SERVICE
TECHNICAL SERVICE
You may have further questions about this heater. If so, contact DESA
International’s Technical Service Department at 1-866-672-6040.
When calling, please have your model and serial numbers of your
heater ready.
You can also visit DESA International’s Technical Service web site
at
www.desatech.com.