background image

105331-01C

11

11

For more information, visit www.desatech.com

For more information, visit www.desatech.com

PARTS LIST

MODELS: BLP50VA, REM50PVA
RLP50VA, RM50PVA

This list contains replaceable parts used in your heater. When
ordering parts, follow the instructions listed under Replacement
Parts
 on page 12 of this manual.

PARTS LIST

Models BLP50VA, REM50PVA, RLP50VA, RM50PVA

KEY

PART

NO.

NO.

DESCRIPTION

QTY.

1

       **

Combustion Chamber

1

2

M11084-26

Hex Tap Screw, #10-16 x 3/8"

7

3

105333-03AB

Outer Shell (BLP50VA)

1

105333-02

Outer Shell (RM50PVA and REM50PVA)

1

105333-01

Outer Shell (RLP50VA)

1

4

104786-01

Handle Kit

1

5

M11143-1

Bushing, Strain Relief

1

6

101480-12

Wire Assembly

1

7

M11084-27

Hex Tap Screw, #12-14 x 1/2"

3

8

099393-03

Knob, Control

1

9

105341-01

Burner Assembly

1

10

099539-01

Electrode Ignitor

1

11

M11084-38

Hex Tap Screw, #8-18 x 3/8"

1

12

101478-03

Fan

1

13

105332-01

Motor

1

14

103863-01

Fan Guard

1

15

097384-02

Captive Washer Nut

3

16

097968-05

Hex Screw, #4-40 x 1/2"

2

17

NPC-00C

Hex Nut, #4-40

2

18

101481-04

Thermal Switch

1

19

097776-01

Universal Bushing

1

20

099237-01

Thermocouple Nut

2

21

104146-01

Thermocouple

1

22

103921-01

Valve/Orifice Assembly

1

23

102445-01

Piezo Ignitor

1

24

078978-03

Sleeve Cap

1

25

105335-01

Base Assembly

1

26

099202-02

Steel Rivet, 1/8"

1

27

M12461-14

Hex Screw, 8-32 x 3/8

2

28

098219-25

Cord, Power Supply

1

PARTS AVAILABLE - NOT SHOWN

097941-28

Tradename Decal (RLP50VA)

2

097647-10

Tradename Decal (BLP50VA)

2

097941-29

Tradename Decal (RM50PVA)

2

099596-16

Tradename Decal (REM50PVA)

2

103867-05

General Information Decal

1

103869-03

Operation Decal

1

099672-01

Notice Decal

1

** Not a field replaceable part.

Summary of Contents for BLP50VA

Page 1: ...IOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOX IDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRU...

Page 2: ...A 58 and the Natural Gas Installation Code CAN CGA B149 2 This in structs on the safe storage and handling of propane gases Use only the electrical voltage and frequency specified on model plate The e...

Page 3: ...r is designed to operate with a minimum 20 pound propane tank You may need two or more tanks or one larger tank in colder weather Use a 100 pound tank for longer operation or in very cold weather Less...

Page 4: ...ator assembly attaches to the propane gas supply This provides fuel to the heater TheAirSystem Themotorturnsthefan Thefanpushesairintoand around the combustion chamber This air is heated and provides...

Page 5: ...0 feet long use 14 AWG rated cord 4 Plug extension cord into a 120 volt 60 hertz 3 hole grounded outlet Motorwillstart Fanwillturn forcingairoutfrontofheater 5 Open propane supply valve on propane tan...

Page 6: ...nk s in safe manner See Chapter 5 of Stan dard for Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 Follow all local codes Always store propane tanks outdoors 2 Place plastic cover caps...

Page 7: ...Fan page 8 4 Clean heater See Maintenance page 6 POSSIBLE CAUSE 1 No electrical power to heater 2 Fan hitting inside of heater shell 3 Fan blades bent 4 Defective motor 1 User did not follow installat...

Page 8: ...r If any part of the electrical system is damaged you must replace motor MOTOR 1 Remove three screws that attach fan guard to heater shell 2 Remove motor and fan guard from heater shell see Figure 10...

Page 9: ...gh bushing in heater shell Attach ignitor wire to piezo ignitor 7 Set gap between ignitor electrode and target plate to 17 see Figure 16 SERVICE PROCEDURES Continued Rear Head Figure 15 Removing Ignit...

Page 10: ...more information visit www desatech com 28 27 15 17 18 21 1 2 3 2 4 6 7 9 11 21 22 23 24 25 19 2 10 26 16 12 13 14 5 20 20 8 ILLUSTRATED PARTS BREAKDOWN MODELS BLP50VA REM50PVA RLP50VA RM50PVA ILLUST...

Page 11: ...nob Control 1 9 105341 01 Burner Assembly 1 10 099539 01 Electrode Ignitor 1 11 M11084 38 Hex Tap Screw 8 18 x 3 8 1 12 101478 03 Fan 1 13 105332 01 Motor 1 14 103863 01 Fan Guard 1 15 097384 02 Capti...

Page 12: ...Not Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s either contact your nearest Parts Cen tral or call DESA International at 1 866 672 6040...

Page 13: ...Dyna Glo Dura Heat Paulin Coleman Vogelzang American Other ___________________________________ 12 Who selected the product Male Female Both 13 Level of Education of Purchaser High School Vocation Tec...

Page 14: ...2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TM TAPE TAPE...

Page 15: ...IN G klsuiejlb oeklhi kokle log e pdl lklsuie jlb oeklhi e pdl lklsuie jlb oeklhi kokle log e pdl l klsuiejlb oeklhi kokle log e pdl l klsuiejlb oeklhi kokle log e pdl l klsuiejlb oeklhi kokle log e p...

Page 16: ...s no responsibility for indirect incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not ap...

Reviews: