5
100165
Air For Combustion
Air For Heating
THEORY OF
OPERATION
The Fuel System:
The hose/regulator assembly attaches to the propane gas
supply. The propane gas moves through the solenoid valve and out the nozzle.
The Air System:
The motor turns the fan. The fan pushes air into and around
the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System:
The burner control sends voltage to the ignitor. The
ignitor ignites the fuel and air mixture.
The Safety Control System:
This system causes the heater to shut down if the
flame goes out. The motor will continue to run, but no heat is produced.
Motor
Clean
Heated
Air Out
(Front)
Hose/Regulator
Assembly
Figure 2 - Cross Section Operational View
Power
Cord
Cool Air In
(Back)
Ignitor
Fan
Burner Control
Combustion
Chamber
Nozzle
Solenoid
Valve
High Limit
Summary of Contents for BCLP375
Page 15: ...15 100165 NOTES...
Page 34: ...18 100165 REMARQUES...
Page 35: ...19 100165 REMARQUES...