background image

6

106815

PORTABLE GASOLINE GENERATORS

®

GROUND FAULT CIRCUIT
INTERRUPTER RECEPTACLE

All models have a 120-volt ground fault
circuit interrupter (GFCI) receptacle. The
GFCI receptacle is on the control panel or top
cover of alternator (models RGH3000 and
RGH3000PR only). The GFCI protects you
against hazardous electrical shock caused
when your body becomes a path through
which electricity travels to reach ground.
This could happen when you touch an appli-
ance or cord that is ‘live’ through faulty
mechanism, damp or worn insulation, etc.

When protected by the GFCI, you may still
feel a shock, but the GFCI should cut it off
quickly. A person in normal health should
not receive serious injury.

 Note:

 Infants and

very small children may still be affected.

Test Procedure

Check the GFCI receptacle every month.
This insures it is working right.

1.

Push black TEST button. Red RESET
button should pop out. This should trip
GFCI, resulting in no electrical power
at receptacle. Verify this by plugging
test lamp with good bulb into recep-
tacle. If lamp does not work, GFCI re-
ceptacle is good.

120/240 VOLT

Position

120 VOLT ONLY

Position

Figure 3 - Full Power Selector Switch

GENERATOR
FEATURES

OIL ALERT SYSTEM

The oil alert system protects the engine from
low oil damage. This system automatically
shuts down the engine and prevents engine
restarting if the oil level falls too low.

Note:

 When this happens, the engine switch

remains in the ON position. The oil alert
system is wired into the ON/OFF Switch.

If this system shuts down the engine, the
engine will not start until you add oil. Add
oil to engine (see Engine Oil, page 7).

Note: 

Operate generator on a level surface.

If not level, the oil may flow away from the
oil level sensing device. This will cause the
oil alert system to shut down engine.

See engine owner’s manual for more
information.

Figure 2 - Engine Switch Location

HONDA

OFF

ON

START

ENGINE SW

CIRCUIT
 BREAKER

ON/push OFF

FULL POWER SELECTOR
SWITCH

All models except RGH3000, RGH3000PR,
RGH7500AIE, and RGH11000AIE have a
full power selector switch on the control
panel. The switch has two positions: 120
VOLT ONLY, and 120/240 VOLT.

120 VOLT ONLY:

 This position sends full

power to the 120V receptacles only. 240V
power is not available. Use this position
when powering 120V items only.

120/240 VOLT: 

This position sends full power

to the 120/240V receptacle. It also powers the
120V receptacles at reduced wattage capacity.

IMPORTANT:

 Do not move the full power

selector switch while powering electrical
items. Unplug all items before moving switch.
Failure to do so can damage switch. Models
RGH3000, RGH3000PR, RGH7500AIE, and
RGH11000AIE do not have this switch. These
models provide full power to all receptacles.

ELECTRIC START

(Models RGH5500AIE,
RGH7500AIE, and RGH11000AIE)

Models RGH5500AIE, RGH7500AIE, and
RGH11000AIE have electric starters. A bat-
tery is not supplied with generator. You
must provide a 12-volt, 32-amp-hour bat-
tery. For more battery information, see Bat-
tery,
 page 8.

ENGINE SW

          ON

OFF

Models RGH3000
and RGH5500A

Models
RGH5500AIE,
RGH7500AIE, and
RGH11000AIE

AUTO-IDLE SYSTEM

The Auto-Idle System allows the engine to
idle down or run at a slower speed when the
generator is not being used to supply power.
The Auto-idle system can be turned ON or
OFF by a rocker switch on the control panel.
When the switch is in the OFF position, the
engine runs at full speed all of the time. When
the switch is in the ON position, the engine
slows down to idle speed until an electrical
load is applied. When a load is applied to the
generator (an electrical item is plugged in and
turned on) the engine speeds up to the preset
speed required to produce the correct voltage.

IMPORTANT: 

A minimum current load of

1 Amp is required to disengage the auto idle
solenoid and cause the engine to come up to
speed for correct voltage. Powering items at
reduced engine speed will damage genera-
tor and powered items.

 WARNING: If RESET button

does not pop out, do not use the
GFCI receptacle. Contact a quali-
fied electrician for repairs.

Model
RGH3000PR

Summary of Contents for And Rgh11000aie

Page 1: ...N MANUAL IMPORTANT Read and understand this manual before operating or servicing generator Improper use of generator can cause serious injury Keep this manual for future reference Generator Models RGH...

Page 2: ...erence It is your guide to safe and proper operation of this generator Safetyinformationappearsthroughoutthese instructions Pay close attention to them Below are definitions for the safety infor matio...

Page 3: ...e or flames if it vibrates at high levels if it has a damaged receptacle 12 Keep generator and nearby areas clean Keep generator free of oil mud and other foreign matter Remove anything that creates s...

Page 4: ...tput drops 1 for each 10 temperature rise above 60 F Very low temperatures may make the engine hard to start See engine owner s manual for more information GENERAL INFORMATION Reddy portable generator...

Page 5: ...p 30 Amp 30 Amp 120 V Full Power Switch No No Yes No No 120 240 V 50 A No No No No Yes General Honda Engine H P 5 5 5 0 9 13 20 Honda Model GX160K1VX GC160VXA GX270VA GX390K1VXE GX620VXA3 Fuel Type Ga...

Page 6: ...push OFF FULL POWER SELECTOR SWITCH AllmodelsexceptRGH3000 RGH3000PR RGH7500AIE and RGH11000AIE have a full power selector switch on the control panel The switch has two positions 120 VOLT ONLY and 12...

Page 7: ...11000AIE only the oil should be between the two dots on dipstick 3 If level is low fill to top of oil filler neck see Figure 7 For Model RGH11000AIE only fill to top dot on dipstick Only use oil recom...

Page 8: ...l Cage Washers Lock Nuts Handle BATTERY Models RGH5500AIE RGH7500AIE and RGH11000AIE WARNING Battery gives off explosive gases Keep sparks flames and cigarettes away Do not remove or install battery c...

Page 9: ...evels are full Make sure battery is charged See engine owner s manual for more information Battery Hook Bolt Nut Grounding generator helps prevent electric shock from a ground fault condition Locate g...

Page 10: ...generator can power Do this before using generator Use the following four step method It will help you select a load that is not too large Make sure total wattage of all electrical loads does not exc...

Page 11: ...to that manual for questions concerning engine operation USING RECEPTACLE Note Do not exceed amperage rating of receptacles Exceeding rating will trip re ceptacle circuit breaker Usereceptaclesproperl...

Page 12: ...gine be fore adding electrical loads 1 Make sure gasoline tank is full See Fuel page 7 for fuel information 2 Move fuel valve lever to the ON posi tion except on Model RGH3000PR see Figure 19 3 Move c...

Page 13: ...ine Allow engine to warm up with no load for five minutes Solenoid Mounting Bracket Bolt OF F EN GI NE Solenoid Mounting Bracket M8 Nut Figure 27 Solenoid Bracket Location Models RGH5500AIE and RGH750...

Page 14: ...nerator page 10 2 Start engine Let engine reach full speed 3 Connect electrical loads one at a time If the load consists of electric motors start them first Always start the larg est first Start each...

Page 15: ...t The throttle is locked in preset position Do not adjust throttle Preset position lets en gine run at 3600 RPM under load The engine must maintain 3600 RPM for generator to create cor rect voltage Ru...

Page 16: ...B la c k White Resistance in Ohms Stator Stator Rotor Rotor Capacitor Main Auxiliary Primary Secondary MFD Diodes 2 Model Winding Winding Winding Winding 450 Volt 800 Volt RGH3000 RGH3000PR 1 6 5 9 6...

Page 17: ...A or 30A Circuit Breaker 20A Green 120V 15A Receptacle White Black Duplex White To Solenoid s1 s2 Full Pwr Selector Switch T2 Red Black Black Red White Hour Meter Black White Figure 34 Wiring Diagram...

Page 18: ...Black Red Red Red Red Yellow Yellow White White Auto Idle Control Board Yellow White White White Circuit Breaker 30A Circuit Breaker 30A Circuit Breaker 45A Circuit Breaker 45A Green T2 Green Black Re...

Page 19: ...n calling DESA International have ready your name your address model and serial number of your generator how generator is malfunctioning purchase date Usually we will ask you to return the defec tive...

Page 20: ...1 21 26327006 Bolt 5 16 24 x 5 8 4 22 WLE 5 Lock Washer 5 16 4 PARTS AVAILABLE NOT SHOWN 099866 03 Safety Information Decal 1 099866 04 Safety Information Decal 1 099867 02 Operation Decal 1 KEY PART...

Page 21: ...3002 Fan Bracket 1 15 27003015S 27003015S Screw M8 x 20 4 16 099891 01 099891 01 Rotor Nut Flanged 8mm 1 17 099892 01 099892 01 Foam Pad 1 18 099842 02 099842 04 Draw Bolt 1 19 27003003 27003003 Beari...

Page 22: ...Draw Bolt 103188 01 1 4 Fan 103191 01 1 5 Balancing Disc 103192 01 1 6 Lifting Eyes 103193 01 2 7 D E Bracket 103194 01 1 8 N D E Bracket 103195 01 1 9 Mounting Bolts 099847 05 4 10 Nuts 099891 01 4...

Page 23: ...under Replacement Parts on page 19 of this manual 1 2 3 4 5 3 4 3 4 5 3 4 3 6 6 7 9 3 3 3 7 4 4 3 4 5 8 KEY PART NO NUMBER DESCRIPTION QTY 1 105155 01 Roll Cage 1 2 099754 01 Engine Spreader 1 3 NEC 5...

Page 24: ...D PARTS LIST For Models RGH5500A RGH5500AIE and RGH7500AIE Fuel Tank and Roll Cage 3 24 3 24 12 23 22 7 8 6 6 27 7 25 15 5 26 11 13 21 20 19 F U E L F 10 10 3 4 3 4 1 2 11 16 14 23 14 23 10 9 11 16 13...

Page 25: ...Nut 1 4 20 3 11 NEC 5C NEC 5C Lock Nut 5 16 18 10 12 14138000 14138000 Ground Strap 1 13 099853 02 099853 02 Shock Mounts 3 14 WLE 5 WLE 5 Lock Washer 5 16 3 15 WLI 3 WLI 3 Lock Washer 10 1 16 WP 5C...

Page 26: ...29 36 26 10 37 28 12 10 16 27 2 37 10 10 25 10 9 35 1 7 3 6 5 6 9 10 4 9 10 36 9 24 22 8 12 11 25 37 10 10 21 21 20 20 19 19 18 32 9 31 34 30 33 18 F U E L F 17 10 9 15 14 13 ILLUSTRATED PARTS LIST F...

Page 27: ...5 M10990 3 Bushing 1 16 106988 01 Barbed Connector 1 4 1 17 25985008 Fuel Line 1 18 105035 01 Handle 2 19 103046 01 Grip 2 20 103057 01 Plug 2 21 H8C5 20C Bolt 5 16 18 x 2 5 4 22 099750 01 Bolt J Hook...

Page 28: ...60 01 099760 01 Bushing 1 11 100410 01 100410 01 Sems Screw 8 18 x 1 2 4 12 100149 01 100149 01 Control Box 1 13 22261000 22261000 U Nut 8 14 099997 01 099997 01 Switch Plug 1 103348 02 103348 04 Cont...

Page 29: ...x 1 15 100366 01 Rocker Switch 1 16 15324000 120V 15A Duplex Receptacle 1 102927 01 Control Panel Assembly 1 100177 05 Panel Schematic Diagram 1 103257 01 Auto Idle PC Board Kit 1 103258 02 Solenoid A...

Page 30: ...GENERATORS DESA IN TERNATIO NAL S2 S1 L1 L2 1 2 4 5 3 8 7 14 13 10 12 11 9 8 10 6 Control Board Assembly and Mounting Solenoid Assembly and Mounting ILLUSTRATED PARTS LIST For Solenoid and Control Bo...

Page 31: ...26514000 Lock Nut 10 32 4 6 100324 03 Solenoid Assembly Includes Plunger Nut and Lock Washer 1 7 103812 01 Retaining Ring 1 8 100755 02 Linkage Rod 1 100755 01 Linkage Rod 1 9 22822000 Roll Pin 1 10...

Page 32: ...re the responsibility of the owner DESAInternationalmakesnowarrantywithrespecttotheengineandenginecomponentsnotofitsmanufacture Theyaresubjecttowarranties of their manufacturers To the full extent all...

Reviews: