background image

www.desatech.com

116557-01A

7

OPERATION

Continued

4.  When the pilot lights, continue to hold the but-

ton depressed for 30 seconds, then release.

5.  If pilot goes out, wait 5 minutes and repeat the 

lighting procedure.

6.  When the pilot remains lit, open the ball valve 

(turn knob counterclockwise) to light main 

burner. Partially close valve to regulate heat 

output.

STORAGE

 CAUTION: Disconnect heater 

from propane supply tank(s).

 CAUTION: Be careful not to 

locate fingers in groves on side 

of  heater,  in  vent  holes  or  on 

bottom  of  shell  when  collaps-

ing shell to the down position. 

Severe cuts may occur. Always 

wear  hand  protection  when 

grasping bare metal.

1.  The heater should be inspected before each use 

and at least annually by a qualified person.

2.  Before each use, check the soft "O" ring seat at 

the bullnose of the POL fitting. If the "O" ring 

is cut, scuffed or otherwise damaged, replace 

the POL fitting with part number LPA4020.

3.  Turn off the gas at the propane/LP gas supply 

cylinder(s) when the heater is not in use.

4.  Heater is to be stored indoors. The connection 

between propane/LP gas supply cylinder(s) 

and heater must be disconnected, cylinder(s) 

removed from the heater and stored outdoors 

in accordance with Chapter 5 of the 

Standard 

for Storage and Handling of Liquefied Petro-

leum Gases ANSI/NFPA 58 

and

 CSA B149.1, 

Natural Gas and Propane Installation Code

.

5.  Store in a dry, clean and safe place.

MAINTENANCE

  WARNING:  Never  attempt 

to  service  heater  while  it  is 

connected  to  propane  supply, 

operating or hot. Severe burns 

can occur.

1.  Keep heater clean.
2.  Inspect heater before each use. Check connec-

tions for leaks. Apply mixture of liquid soap 

and water to connections. Bubbles forming 

show a leak that must be corrected. Correct 

all leaks at once.

3.  Inspect hose/regulator assembly before each 

use. If hose is highly worn or cut, replace.

4.  Have heater inspected yearly by a qualified 

service person.

Figure 8 - Starting Heater

Ignitor 
Button

Ball Valve Control 
Knob Button

TO STOP HEATER

1.  Securely close valve on the propane cylinder.
2.  Continue to operate heater until all fuel in the 

hose has burned.

3.  Fully close the ball valve.

TO RESTART HEATER

1.  Securely close valve at propane cylinder.
2.  Wait 5 minutes.
3.  Restart heater by following 

To Start Heater

page 6.

Safety Pilot 
Valve

Summary of Contents for 80-CC

Page 1: ...xiation carbon monoxide poisoning and or electrical shock Onlypersonswhocanunderstandandfollowtheinstruc tions should use or service this heater Ifyouneedassistanceorheaterinformationsuchasanin structions manual labels etc contact the manufacturer Save this manual for future reference For more information visit www desatech com 200 000 BTU HR TABLE OF CONTENTS Safety Information 2 Unpacking 3 Theo...

Page 2: ... odor making agent is added to propane gas The odor helps you detect a propane gas leak However the odor added to propane gas may fade Propane gas may be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this heater 1 Install and use heater with care Follow all local ordinances and c...

Page 3: ... to heater when not in use 27 Use only original replacement parts This heater must use design specific parts Do not substitute or use generic parts Improper replacement parts could cause serious or fatal injuries UNPACKING 1 Remove all packing items applied to heater for shipment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from car...

Page 4: ...anifold Average Temperature Number At Tank Location Of Tanks 80 000 Btu models 20 F 6 7 C to 60 F 15 6 C 1 0 F 17 8 C to 20 F 6 7 C 2 200 000 Btu models 20 F 6 7 C to 60 F 15 6 C 2 0 F 17 8 C to 20 F 6 7 C 3 Less gas is vaporized at lower temperatures Your local propane gas dealer will help you select the proper supply system INSTALLATION WARNING Review and un derstand the warnings in the SafetyIn...

Page 5: ...s the check valve closing To reset the excess flow check valve close propane supply valve and open again slowly 5 Slightly depress and turn control knob counter clockwise to the LO position see Figure 5 6 With the control knob pushed all the way in press and release the piezo ignitor button Keep pressing piezo ignitor button until the burner lights Hold control knob down for a maximum of 15 seconds...

Page 6: ...he heater OPERATION Continued TO STOP HEATER 1 Tightly close propane supply valve on propane tank s Allow heater to burn remaining fuel in hose 2 Shut off burner Do this by pushing in the control knob and turning clockwise to the OFF position TO RESTART HEATER 1 Wait five minutes after stopping heater 2 Restart heater by following To Start Heater page 5 WARNING Review and un derstand the warnings i...

Page 7: ...ors The connection between propane LP gas supply cylinder s and heater must be disconnected cylinder s removed from the heater and stored outdoors in accordance with Chapter 5 of the Standard for Storage and Handling of Liquefied Petro leum Gases ANSI NFPA 58 and CSA B149 1 Natural Gas and Propane Installation Code 5 Store in a dry clean and safe place MAINTENANCE WARNING Never attempt to service h...

Page 8: ...3 Tighten connection or replace thermocouple 4 Replace automatic control valve 1 Turn valve counter clockwise to HIGH 2 Replace gas orifice 3 Check gas supply check regulator output 4 Consult propane gas supplier OBSERVED FAULT Burner fails to light Pilot lights but goes out when automatic control valve button is released 200 000 Btu models only Burn rate is low POSSIBLE CAUSE 1 Propane supply valv...

Page 9: ...mber SPECIFICATIONS 80 000 Btu 200 000 Btu Type of Gas Propane LP Only Propane LP Only Gas Supply Pressure to regulator Maximum Bottle Pressure Bottle Pressure Minimum 5 psig 34 5 kPa 15 psig 103 kPa Gas Supply Pressure regulator out 25 W C 63 5 cm 10 psig 68 9 kPa Ignition Piezo Ignitor Piezo Ignitor Minimum Ambient Temp Rating 0 F 17 8 C 0 F 17 8 C Rating 40 000 80 000 Btu hr 75 000 200 000 Btu ...

Page 10: ...www desatech com 116557 01A 10 ILLUSTRATED PARTS BREAKDOWN MODELS 80 CC RCP80VC REMCP80VC SPC 80CC AND TC80VC 1 2 3 4 10 22 21 23 6 8 7 13 12 16 9 14 15 18 17 19 20 5 11 ...

Page 11: ...tor 1 14 116556 01 Nozzle 1 15 116570 01 Fuel Tube Kit 1 16 103929 01 Burner Tube Kit 1 17 099460 01 Brass Hex Cap 1 18 116554 01 Automatic Valve 1 19 113812 02 Adapter 1 4 FPT x 1 4 MPT 1 20 113795 01 Female Elbow Fitting 1 4 FPT x 3 8 FLR 1 21 113776 01 Hose Assembly 10 foot 1 22 113862 01 Regulator 1 23 113791 01 POL Excess Flow 1 PARTS AVAILABLE NOT SHOWN 113822 11 Tradename Decal Reddy 1 1138...

Page 12: ...www desatech com 116557 01A 12 3 10 24 23 8 4 13 15 5 31 14 22 28 20 16 17 25 1 26 2 21 19 18 9 27 29 6 23 12 7 30 ILLUSTRATED PARTS BREAKDOWN MODELS 200C RCP200V A SPC 200C AND TC200V A ...

Page 13: ...01 Thermocouple 1 18 113818 01 POL Excess Flow 1 19 113819 01 Regulator 1 20 113793 01 Ball Valve 1 21 102445 01 Piezo Ignitor 1 22 113794 01 Valve Nut 1 2 28 1 23 113795 01 Female Elbow Fitting 1 4 FPT x 3 8 FLR 3 24 113796 01 Retaining Ring 1 25 113797 01 Ignitor Electrode 1 26 113798 01 Heat Shield 1 27 113799 01 Pilot Orifice 1 28 113800 01 Washer Flat 1 29 113801 01 Elbow Fitting 1 8 FPT x 1 4...

Page 14: ...se warranties are extended only to the original retail purchaser when proof of purchase is provided Factory Reconditioned Heaters DESA Heating Products warrants this factory reconditioned heater and any parts thereof to be free of defects in materials and workmanship for thirty 30 days from the date of first purchase when operated and maintained in accordance with the manufacturer s instructions Th...

Reviews: