![Desa 35,000 BTU/Hr Models Owner'S Manual Download Page 4](http://html.mh-extra.com/html/desa/35-000-btu-hr-models/35-000-btu-hr-models_owners-manual_2486000004.webp)
4
102437
THEORY OF
OPERATION
The Fuel System:
The air pump forces air through the air line. The air is then
pushed through the burner head nozzle. This air causes fuel to lift from the tank.
A fine mist of fuel is sprayed into the combustion chamber.
The Air System:
The motor turns the fan. The fan pushes air into and around
the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System:
The electronic ignitor sends voltage to the spark plug.
The spark plug ignites the fuel and air mixture.
The Flame-Out Control System:
This system causes the heater to shut down
if the flame goes out.
Fuel
Filter
Air For Fuel
System
Air For Combustion
And Heating
Fuel
Combustion
Chamber
Air
Intake
Filter
Clean
Heated
Air Out
Cool
Air
In
Air
Output
Filter
Fuel
Tank
Figure 2 - Cross Section Operational View
Burner
Head
Spark
Plug
Motor
Fan
Electronic
Ignitor
Air Line
To Burner
Nozzle
Air Pump
PRODUCT
IDENTIFICATION
Lower Shell
Power Cord
Side Cover
Fuel Tank
Hot Air Outlet
Upper Shell
Flame-Out Control
Reset Button
Fuel Cap
Air Filter
End Cover
Fan Guard
Handle
Figure 1
1. Remove all packing items applied to heater for shipment.
2. Remove all items from carton.
3. Check items for shipping damage. If heater is damaged, promptly inform
dealer where you bought heater.
UNPACKING