background image

8

102318

INSTALLING

NOTICE

A qualified service person must install heater. Follow all local codes.

WARNING ICON

G 001

 WARNING

Before installing in a solid fuel burning fireplace, the chimney flue
and firebox must be cleaned of soot, creosote, ashes and loose paint
by a qualified chimney cleaner. Creosote will ignite if highly heated.
Inspect chimney flue for damage. If damaged, operate heater with
flue damper closed.

WARNING ICON

G 001

 WARNING

Seal any fresh air vents or ash clean-out doors located on floor or wall
of fireplace. If not, drafting may cause pilot outage or sooting. Use a
heat-resistant sealant. Do not seal chimney flue damper.

WARNING ICON

G 001

 WARNING

Never install the heater

• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are

less than 36 inches from the front, top, or sides of the heater

• in high traffic areas
• in windy or drafty areas

WARNING ICON

G 001

 CAUTION

This heater creates warm air currents. These currents move heat
to wall surfaces next to heater. Installing heater next to vinyl or
cloth wall coverings or operating heater where impurities in the air
(such as tobacco smoke) exist, may discolor walls.

IMPORTANT:

 Vent-free heaters add moisture to the air. Although this is beneficial,

installing heater in rooms without enough ventilation air may cause mildew to form
from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

CHECK GAS TYPE

Use only propane gas. If your gas supply is not propane, do not install heater. Call
dealer where you bought heater for proper type heater.

NOTICE

State or local codes may only allow operation of this appliance in a
vented configuration. Check your state or local codes.

Summary of Contents for 24" Variably-Controlled Models

Page 1: ...aintenance can cause injury or property damage Refer to this manual for correct installa tion and operational procedures For assistanceoradditionalinformationcon sultaqualifiedinstaller serviceagency...

Page 2: ...titudes Propane Gas Propane gas is odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no o...

Page 3: ...s If logs ever appear to smoke turn off heater and call a qualified service person Note During initial operation slight smoking may occur due to log curing and heater burning manufacturing residues 10...

Page 4: ...eaters You can operate heater as a vented product by opening flue damper Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pilot is a required feature fo...

Page 5: ...1992 Section 5 3 defines confined space as having an air volume of less than 50 cubic feet 127 cubic cm for each 1000 Btu Hr input rating of all appliances in the space cubic feet equals length x wid...

Page 6: ...heater ___________________ Btu Hr Gas fireplace logs ___________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Example Gas water heater 40 000 Btu Hr...

Page 7: ...f ventilation grills or ducts WARNING ICON G 001 WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in...

Page 8: ...re clothing or other flammable objects are less than 36 inches from the front top or sides of the heater in high traffic areas in windy or drafty areas WARNING ICON G 001 CAUTION This heater creates w...

Page 9: ...ont Width Rear Width 24 17 14 26 18 MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size Side Wall Ceiling Floor 24 16 42 5 Carefully follow the instructions below This will ensure safe insta...

Page 10: ...metal you must have non combustible material behind it Non combustible material must extend at least 8 up If non combustible material is less than 12 you must install the fireplace hood accessory See...

Page 11: ...he hood accessory to deflect heat away from your mantel shelf See chart below and Figures 6 and 7 for minimum clearances IMPORTANT If you cannot meet these minimum clearances you must operate heater w...

Page 12: ...Minimum Fireplace Clearances Above Combustible Flooring If your installation does not meet the above minimum clearances you must operate the logs only with the flue damper open OR raise the mantel to...

Page 13: ...number 1 or 2 above apply to you you must permanently open chimney flue damper You must install the damper clamp accessory to order see Accessories page 31 This will insure vented operation see Figur...

Page 14: ...pproved flexible gas hose to gas regulator of heater see Figure 11 IMPORTANT Hold gas regulator with wrench when connecting flexible gas hose 2 Locate mounting brackets bolts and nuts in hardware pack...

Page 15: ...e external regulator between the heater and propane supply Installation Items Needed Before installing heater make sure you have the items listed below external regulator supplied by installer see pag...

Page 16: ...14 page 17 Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves WARNING ICON G 001 CAUTIO...

Page 17: ...Supply Piping system Test Pressures In Excess Of 1 2 PSIG 1 Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater...

Page 18: ...l shutoff valve see Figure 16 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks at once Pressure Testing Heater Gas Connections 1 Open manual shutoff...

Page 19: ...th heater 1 Place front logs 1L and 1R on top of the grate Make sure the notches in the bottom of the logs fit over the grate prongs see Figure 17 Push back of logs flush with metal grate bar Figure 1...

Page 20: ...Log 3 Peg Grate Prong Grate Prong Rear Burner Groove in Back of Log Groove in Back of Log Figure 19 Installing Rear Log 3 4 Place the top middle log 4 on the bottom middle log 2 Make sure the pegs of...

Page 21: ...back log and the top middle log Make sure the peg on the rear log is in the hole in the bottom of the crossover log The crossover log should fit in the cutout of the top middle log see Figure 21 Figu...

Page 22: ...ntrolknob Neverusetools Iftheknob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosio...

Page 23: ...seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 This heater has a safety inter lock system Wait one 1 minute for system to reset befo...

Page 24: ...ater could produce increased levels of carbon monoxide If front burner flame pattern shows yellow tipping followinstructionsatbottomofthispage Yellowflameonrear burner is normal FRONT BURNER FLAME PAT...

Page 25: ...object to clean ODS pilot This can damage ODS pilot unit POSSIBLE CAUSE 1 Ignitor electrode not con nected to ignitor cable 2 Ignitor cable pinched or wet 3 Piezo ignitor nut is loose 4 Broken ignitor...

Page 26: ...Replace thermocouple 7 Replace control valve OBSERVED PROBLEM When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is relea...

Page 27: ...e nance page 25 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Refer to Air for Com bustion and Ventilation requirements page 5 1 Turn control knob to LO position and let...

Page 28: ...panding while heating or contracting while cooling 1 Heater burning vapors from paint hair spray glues cleaners chemi cals new carpet etc See IMPORTANT statement above 2 Low fuel supply 3 Gas leak See...

Page 29: ...W C Inlet Gas Pressure in of water Maximum 14 Minimum 11 Shipping Weight 38 lbs For the purpose of input adjustment When gas pressure is too low pilot will not stay lit burners will have delayed igni...

Page 30: ...ESA International have ready your name your address model number of your heater how heater was malfunctioning type of gas used propane or natural gas purchase date Usually we will ask you to return th...

Page 31: ...TOFF VALVE GA5010 For all models Manual shutoff valve with 1 8 NPT tap Fits 1 2 NPT pipe BLACK FIREPLACE HOOD GA6050 For all models Helps deflect heat away from mantel or wall above fireplace BRASS FI...

Page 32: ...32 102318 ILLUSTRATED PARTS BREAKDOWN 27 30 27 28 29 6 7 8 29 29 25 10 9 10 11 12 13 15 14 16 20 22 23 28 1 28 2 25 19 18 24 21 27 17 7 1 7 2 26 4 5 3 2 1L 1R...

Page 33: ...Ignitor Cable 1 11 102445 01 Piezo Ignitor 1 12 098867 08 Gas Regulator 1 13 M11084 38 Screw 2 14 100996 02 Pipe Nipple 1 15 098354 01 Control Knob 1 16 102013 01 Control Rod 1 17 100000 01 Cotter Pin...

Page 34: ...__________ ________________________________________________________________ ________________________________________________________________ ___________________________________________________________...

Page 35: ...__________ ________________________________________________________________ ________________________________________________________________ ___________________________________________________________...

Page 36: ...tions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accide...

Reviews: