Page 42 of 45
5.6
Troubleshooting
FAULT
DETECTED
POSSIBLE
CAUSE
SOLUTION
RECOMMENDED
The vacuum cleaner will
not start
-
No power supply
Switch
-
Check for the presence of voltage
in the socket
-
Check the condition of the plug
and the power cable
-
Reset the magneto-thermal
switch
-
Contact DEPURECO technical
assistance
-
circuit breaker
tripped
Irregular suction
-
Clogged filters
-
Clean any clogged filters. If this
solution is not effective, replace
it.
-
Clogged suction
tube
-
Check suction tube and clean it.
Excessive noise from
motor
-
Faulty pump
-
Contact DEPURECO technical
assistance