6.1. Proximity Switch Adjustment
1. Disconnect screwdriver from air supply.
2. Unscrew air connection.
3. With the bit in the screwdriver, activate the push-to-start and
c o n t i n u e t o h o l d t h e s c r e w d r i v e r d o w n
throughout
this procedure!
4. Measure dimension „x“ by means of a sliding caliper (see Picture 1)
5. Adjust the sensor-front surface to dimension „x“ less 0.3 mm to the
contact surface (see Picture 2) and than tighten it with nut.
6. Assemble air connection.
Picture
1
Picture
2
proximity switch
nut