5-4
Shut down
(1) Turn OFF the circuit breaker of the load.
(2) Turn OFF the circuit breaker of the machine.
circuit breaker of the load
Circuit breaker of the machine
(3) Set the throttle lever in "START / IDLING"
position and put the machine in cooling operation
for about 5 minutes.
cooling operation for about 5 min.
(4) Set the starter switch in "STOP" position.
The engine will stop immediately.
(5) Remove the key from the starter
switch and keep it at hand.
(6) Check the panel light goes out.
throttle lever
starter switch
stop
(7) Check the amount of fuel. Supply
additional fuel if necessary.
(8) Check for leakage of oil, fuel and
water.
[Note]
For emergency stop, keep pushing
the "EMERGENCY STOP" button
until the engine stops.
emergency stop button
-