![Denyo DCA-10LSX Instruction Manual Download Page 46](http://html1.mh-extra.com/html/denyo/dca-10lsx/dca-10lsx_instruction-manual_2485059046.webp)
8-6 Check/every 500 hours
(1) Replace air cleaner element
The element should be replaced referring to "Clean air cleaner element" (See p.40)
every 500 hours or 2 years.
In situations where the generator has not been operated for 500 hours or more, as a
general rule, the air cleaner will need to be replaced after it has been cleaned 6 times.
(2) Clean radiator
When the fin or tube is blocked, it should be cleaned with steam or running water.
Do not use a high pressure washer to prevent damage to the fin and tube.
(3) Adjust fuel injection nozzle (DCA-6LSX)
8-7 Check/every 1000 hours
(1) Clean inside of fuel tank
Drain the fuel in the fuel tank completely, and wash out
deposits and water collected inside the tank.
(2) Adjust fuel injection nozzle (DCA-10LSX)
8-8 Check/every 2000 hours
(1) Measure the engine compression pressure
(2) Check the valve clearance
(3) Replace radiator water (if LLC is used)
(4) Check nylon and rubber hose
Check on the nylon and rubber hose whether they are hardened or deteriorate.
Contact distributor or our office to replace the nylon hose and rubber hose, if
necessary.
.
(5) Checking of terminals and connections
Check main and sub circuits whether there are any abnormalities such as loosening,
corrosion, burning, etc.
8-9 Other Checks and Maintenance
(1) Check lining
Check on the lining whether it deteriorates greatly, or it is stained by clinging o f oil
or the like, or it is removed. Contact distributor or our office to replace tbe lining, if
necessary.
42