14
15
3.2.7 Clear Accessories
While in Setup mode, enter “* 22 * password *” (
DEFAULT PASSWORD:1234
)on the control panel to
clear all the connected accessories.
4. ENTER SETUP MODE
1.Press key #, then press key 2 on the control panel to enter setup mode.
4.1 Ringing Time of the Siren
Example: Set the ringing time to be 5 minutes
Enter into Setup mode, type “*1*5*“
You hear “Operation succeeded”: the setup is successful.
Note
The ringing time can be set from 1 to 9 minutes. Default setting: 5 minutes.
4.2 Exit Delay & Entry Delay
Example: Program exit delay to be 60 seconds
Enter into Setup mode, type “*2*60*“
You hear “Operation succeeded”: the setup is successful.
Note
The delay time can be set from 0 to 300 seconds.
Default setting: no delay (0 seconds).
Example: Program entry delay to be 50 seconds.
Enter into Setup mode, type “*3*50*”
You hear “Operation succeeded”: the setup is successful.
Once the function has been set, the panel will beep every second after having armed the system. The
beeps will speed up in the last 15 seconds. If an intruder is detected, the alarm and the dialing will be
delayed accordingly.
4.3 Change Password
To register an additional Denver siren, refer to the instructions provided in the manual that comes
with your siren.
For more information on sirens and accessories compatible with Denver security systems, visit our
website denver-electronics.com
3.2.6 Zone Setup of Accessories
Every detector can be assigned to 4 different categories of zones: Home Mode Zone, Delay Zone,
Normal Zone and 24hZone. To assign a detector to a zone, open its case and move its jumpers
according to the drawing below:
D0
D3
D0
D3
D3
D0
D0
D3
A. Home Mode zone
B. Normal zone
C. 24h zone
D. Delay zone
Home Mode zone
When the system is armed in Home Mode, the sensors assigned to the Home zone do not trigger an
alarm.
It is recommend to assign motion dectors to the Home zone so that you can have your system armed
in Home Mode when you are home and move inside your home without triggering any alarm.
Delay zone
An entry and an exit delay can be set. In such case, sensors assigned to the “Delay Zone” will not trigger
an alarm during the time of delay set. For example, if you assign a motion detector to the Delay zone
and you set the Entry/Exit Delay to 30 seconds, the motion detector will not trigger an alarm within 30
seconds after you enter your home and within 30 seconds before you leave it so that you can leave and
enter your home without triggering an alarm. Refer to the instructions on page 15 or 25 of this manual
to learn how to set the entry and exit delay.
It is recommended to assign the Door / Window Contact to
the Delay zone.
Normal zone
When the system is armed, if a sensor is triggered, the siren rings out. When the system is disarmed,
sensors do not trigger an alarm.
24h zone
Regardless the system is armed or disarmed, sensors assigned to the 24h zone will trigger an alarm.
It is
recommended to set smoke detectors, gas detectors and outdoor beam sensors in the 24h zone.
Please note DENVER-ASA-40 wireless pet immune motion detector and DENVER-ASA-50 wireless
motion detector are default to be Home Mode zone, other accessories are default to be Normal zone.
User can move the jumpers by tweezers.
Summary of Contents for HSA-120