90
Standard C/ | Crowns, bridges, bar-supported overdentures
The impression for suprastructures on Ankylos
Standard C/ abutments is taken using an Ankylos
Standard transfer cap over the Ankylos Standard
C/ abutments already incorporated in the patient’s
mouth. By doing so, the abutment position is
transferred.
The abutments remain in the mouth after the
impression is taken using the repositioning technique.
On straight abutments, an open tray impression can
be taken as well, using the wax-up screw, long.
Repositioning of one-piece
laboratory analogs
Position the Ankylos Standard
laboratory analog in the transfer
cap and check for a firm fit.
Angled laboratory analogs
Angled Ankylos Standard C/
abutments feature a shortened
groove for transferring the
alignment of the 15° angle. The
position of this groove in the
transfer cap should be observed
when inserting the laboratory
analog.
Block the undercut neck area with
wax prior to fabricating the model
without a mucosa mask.
Mucosa mask
Insulate with silicone lubricant
and inject gingiva casting material
into the impression prior to
casting. By doing so, observe the
manufacturer’s directions.
Step-by-step: Fabricating the model
for purely implant-supported restorations