11. Maintenance

Any  controls  or  maintenance  operations  shall  be 

carried  out  when  the  appliance  has  been  unplugged. An 

improperly operation may be a source of danger.

Dust filter

The periodical control of the filter status is necessary for

the exhaust hood to operate properly.

The dust filters can be reached by unloosing the screws on 

the side of the hood cover and removing the latter.

Replace the filter with an original spare part.

Warning!

An  incorrect  installation  of  the  filter  may  cause 

suction problems and damage the exhaust motor.

Fit  the  hood  cover  back  on  and  tighten  the  previously 

removed screws.

LED light

This  maintenance  operation  must  be  performed  only by 

qualified personnel.

To  replace  proceed  as  per  the  replacement  of  the  filter.  

The  LED stripe  can  be  reached  by  opening  the cover  of 

the  exhaust  hood  (see  fig. 2-3). 

11.1. General cleaning

Clean  the  hood  periodically  without  using  any  abrasive 

cleaner. Avoid ammoniac detergents. 

Use  a  soft  damp  cloth  to  clean  the  safety glass screen 

and  the  lamp  shield.  Do  not  scratch  the  surface  or use 

solvents that opacify the screen.

   

  

12. Problems and solutions

Some inconveniences may affect the proper operation of this 

exhaust hood.

Special  maintenance  operations  shall  be  performed only 

by  experts  who  have  been  authorised  by  our company. 

Disconnect power supply every time it is necessary to operate 

on the interior of the unit.

WHAT TO DO IF …

... the power of the suction stream drops

1) Dust filters  are  full;  check  if  they  still  have  sufficient 

      capacity  and,  if  necessary,  replace  them  (see 

       paragraph 11)

... the exhaust motor does not work

1) The power plug has not been plugged in properly.

2) If the red switch (fan symbol) is in "ON" position and the 

      engine does not work, check that the fuse located inside 

      the hood (see fig. 3) is not broken. If necessary replace it 

      with one of the same type (250 Volt - 16A fuse).

3) If the fuse is intact and the motor does still not work, it is 

      necessary to apply to an expert technician authorised by 

      our offices.

In this case, we advise to send the exhaust hood back to our 

works  or  to  one  of  our  service  centres.  Use  suitable 

packaging for the delivery of the goods and provide the unit 

with the maximum protection.

Any  breakage  or  damage  caused  by  improper  packaging will 

be charged to the client.

... the LED light does not work

1) The power cord may not be plugged in properly.

2) Make sure than the main ON/OFF switch and the green 

      switch is "ON”.

3) If the green switch (light symbol) is in "ON" position and the 

      light  is not  on,  check  that  the  fuse  inside  the exhaust 

      hood (see fig. 3) fits properly or has no failure. If necessary, 

      replace the fuse with another one of thesame type ( 250 

        Volt - 16A).

4) If the fuse is intact and in any case the lamp it still does not 

      work, the intertechnical wind of specialized and authorized 

      personnel from our headquarters.

MAINTENANCE

No part of this manual may be reproduced without the prior permission in writing of DENTALFARM Srl

MI 18 A110 R00

7

Summary of Contents for SHINING BOX

Page 1: ...POLISHING UNIT WITH EXTRACTOR SHINING BOX USER AND MAINTENANCE MANUAL ...

Page 2: ......

Page 3: ...eserves the right to change the features of the models and the accessories supplied for technical or commercial reasons without being forced to update this publication promptly 2 Guarantee DENTALFARM guarantees that the safety and functionality of this polishing unit exhaust hood has been tested by the manufacturer The twelve month guarantee includes the free repair or replacement of faulty parts ...

Page 4: ...ng agency Make sure that all components and complementary accessories are included as listed is the delivery note In case of requests remember to state the purchase date model and serial number shown on the data plate DEN TALFARM shall be free from any liability whatsoever regar ding third parties if the data plate should be removed from the appliance 5 Materials Hood structure made from electroga...

Page 5: ...height recommended height min 85 max 105 cm from the floor for the installation of the unit Fit the two dirt trays near the suction holes Connect to power supply 220 Volt and make sure that the main switch is OFF Fit the polishing unit in the middle of the exhaust hood and connect it to the power supply see fig 1 Lift the protective screen carefully until it is in a safe position to protect the op...

Page 6: ... D 10 Controls The control buttons are on the front right hand side of the exhaust hood The functions are the following A White switch ON OFF To turn on and off the electric circuit of the exhaust hood B Green switch light symbol To turn on and off the LED strip light C Red switch fan symbol To turn on and off the exhaust motor D Black knob To regulate the suction speed Models A110S and A110CS equ...

Page 7: ...r of the unit WHAT TO DO IF the power of the suction stream drops 1 Dust filters are full check if they still have sufficient capacity and if necessary replace them see paragraph 11 the exhaust motor does not work 1 The power plug has not been plugged in properly 2 If the red switch fan symbol is in ON position and the engine does not work check that the fuse located inside the hood see fig 3 is n...

Page 8: ...s supplied appropriately The operator shall not remove any protective devices 2 Check periodically that all parts are not damaged and advise the Company immediately in case of any dangerous conditions 3 Before carrying out any maintenance operations make sure that the appliance is not connected to the power supply 4 Allow repairs to be carried out only by authorised technicians who use original ma...

Page 9: ...DENTALFARM Srl via Susa 9 A 10138 TORINO Italy tel 39 011 4346588 e mail info dentalfarm it web www dentalfarm it ...