APPLICATION

SeaShield FX-70 Jackets
For pumping applications

, pump properly mixed SeaShield FX-225 as follows: Install pumping ports at 90 degrees 

from tongue-and-groove joint, alternating sides. Place the fi rst port approximately 1 ft. (30 cm) from the bottom of 

the jacket. Place subsequent ports at a maximum 5 ft. (1.5 m) vertical spacing, alternating sides. Begin pumping 

from the lowest port and move up from port to port. Do not exceed 10 ft. (3 m) pumping distance from any individual 

port. 

For tremie applications

, make sure the hose extends all the way to the bottom of the form. Fill the form to the 

desired level, allowing water to displace from the top of the form. Depending on the head pressure, depth of pour, 

and size of the vessel, the tremie hose may need to be retracted as the form fi lls to maintain fl ow.

All submerged jackets should be inspected by a certifi ed professional diver during the fi lling process to check for 

leaks and proper placement.

Formed applications, below water
For pumping applications

, pump properly mixed SeaShield FX-225 as follows: Install pumping ports as required 

for the repair. Begin pumping from the lowest port and move up from port to port making sure the form is completely 

fi lled and the water is displaced. Do not exceed form design pressure rating.

For tremie applications

, make sure the hose extends all the way to the bottom of the form. Fill the form to the 

desired level, allowing water to displace from the top of the form. Depending on the head pressure, depth of pour, 

and size of the vessel, the tremie hose may need to be retracted as the form fi lls to maintain fl ow. Do not exceed 

form design pressure rating. 