SAFETY PRECAUSIONS 

Be sure to observe all these safety precautions. 

  Please READ through these instructions carefully. They will enable you to use the scanner 

correctly. 

  Always keep this manual nearby for speedy reference. 

Strict observance of these warnings and cautions is a MUST for preventing accidents that could 
result in bodily injury and substantial property damage. Make sure you fully understand all definitions 
of these terms and symbols given below before you proceed to the text itself. 

 

WARNING 

WARNING 

Alerts you to those conditions that could cause serious bodily injury or death if 
the instructions are not followed correctly. 

CAUTION 

Alerts you to those conditions that could cause minor bodily injury or 
substantial property damage if the instructions are not followed correctly. 

 

SYMBOLS 

A triangle (

) with a picture inside alerts you to a warning of danger. Here you see the 

warning for electrical shock. 

A diagonal line through a circle (

) warns you of something you should not do; it may or 

may not have a picture inside. Here you see a screwdriver inside the circle, meaning that 
you should not disassemble. 

A black circle (

) with a picture inside alerts you to something you MUST do.   

 

WARNING

 

 

Wrong handling of the product against these warning precautions could result in serious bodily injury 
or death. It may lead to electric shock, vision disturbance, impaired skin, injury or burn or will cause 
the product to generate heat or smoke. Be sure to observe the following when using this product. 

 

Effect on implantable medical device

 

This product is a reader/writer of RFID devices using electric waves. Medical device may be 
affected by RFID device in some applications/places. Observe the following precautions to 
reduce the effect for implementing RFID.   
Those wearing an active implantable medical device (AIMD) are required to stay at least 22 
cm away from the antenna part of a fixed or module type RFID device.

 

 

Several current reports indicate that RFID devices may cause malfunctions in AIMDs such 
as implantable cardiac pacemakers, implantable cardioverter-defibrillator. This is attributed 
to general characteristics of electric or electronic devices using radio waves, and not the 
unique features of DENSO WAVE’s products or this product itself.   

Summary of Contents for SE1-HU

Page 1: ...tenna controller both correctly and effectively Also keep it handy for ready reference For more details on using this antenna controller see the User s Manual that is available as a free download from...

Page 2: ...NSO WAVE ii The use of DENSO WAVE s products in a manner for which the same were not intended nor designed or iii The modification of DENSO WAVE s products by other s than DENSO WAVE Any malfunctions...

Page 3: ...n der Richtlinie 1999 5 EG befindet ET Estonian K esolevaga kinnitab DENSO WAVE INCORPORATED seadme HIGH FREQUENCY 13 56MHz TRANSCEIVER vastavust direktiivi 1999 5 E p hin uetele ja nimetatud direktii...

Page 4: ...e cu cerin ele esen iale i cu alte prevederi pertinente ale Directivei 1999 5 CE SK Slovak DENSO WAVE INCORPORATED t mto vyhlasuje e HIGH FREQUENCY 13 56MHz TRANSCEIVER sp a z kladn po iadavky a v etk...

Page 5: ...imits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequenc...

Page 6: ...6 SRRC 1 13 553 13 567MHz 10 42dB A m 100 10 6 13 553 13 567MHz 140kHz 9dB A m 10 2005 423 2 3 4 5 ARIB STD T82 AC XXXXX...

Page 7: ...inside Here you see a screwdriver inside the circle meaning that you should not disassemble A black circle with a picture inside alerts you to something you MUST do WARNING Wrong handling of the produ...

Page 8: ...diately switch off the product Failure to do so could cause fire or electrical shock Do not scratch modify bend twist pull or heat the cable or allow the cable to get pressed under heavy materials The...

Page 9: ...a radio set such as personal radio or amateur radio Doing so could cause malfunction Communications performance may be reduced resulting in malfunction due to mutual interference if there is more tha...

Page 10: ...nge 10 to 50 C freezing not allowed Storage humidity range 35 to 95 RH condensation not allowed Applied standard Japan ARIB STD T82 AC XXXXX Europe R TTE Directive Radio EN302 291 1 2 EMC EN301 489 1...

Page 11: ...mm inch Standard Tolerance Nominal Dimension L Tolerance L 18 0 71 1 2 0 047 18 L 30 1 18 1 5 0 059 30 L 50 1 97 2 3 0 091 50 L 80 3 15 3 0 0 118 80 L 120 4 73 3 8 0 150 120 L 180 7 09 4 5 0 177 180...