Chapter 2 Getting Started the BHT and System Menu
33
Cold-booting the BHT
If a problem persists even after warm-booting the BHT, cold-boot the BHT.
Cold-booting the BHT will erase all data stored in the RAM. It is recommended that important data be
saved into the FLASH folder or uploaded to the host computer.
Cold booting procedure
Turn the BHT off. While holding down the reset button with the stylus, press the
power
key and then
release them. Press the
power
key again, and the BHT cold-boots.
Contents of the memory after warm-/cold-booting the BHT
After warm booting
After cold booting
Data in the FLASH folder
Retained
Retained
Data in other folders
Retained
Erased
Contents of the Registry
Retained
Erased*
Data being edited
Erased
Erased
* If the Registry has been backed up, the backup will apply. For the backup procedure, refer to Section
2.3.4, "[ 2 ] Backing up the Registry."
Application program to run automatically at warm-/cold-boot
If any execution program file (XXXXXX.exe) is stored in the FLASH\StartUp folder, warm- or
cold-booting the BHT automatically runs that program file.
Summary of Contents for BHT-202QW-CE
Page 1: ...BHT 202Q 202QW CE...