48
NOTE FOR SCHEMATIC DIAGRAM
WARNING:
Parts marked with this symbol
z
have critical characteristics.
Use ONLY replacement parts recommended by the manufacturer.
CAUTION:
Before returning the unit to the customer, make sure you
make either (1) a leakage current check or (2) a line to chassis
resistance check. If the leakage current exceeds 0.5 milliamps,
or if the resistance from chassis to either side of the
power cord is less than 460 kohms, the unit is defective.
WARNING:
DO NOT return the unit to the customer until the problem is
located and corrected.
NOTICE:
ALL RESISTANCE VALUES IN OHM. k=1,000 OHM
M=1,000,000 OHM
ALL CAPACITANCE VALUES IN MICRO FARAD.
P=MICRO-MICRO FARAD
EACH VOLTAGE AND CURRENT ARE MEASURED AT
NO SIGNAL INPUT CONDITION.
CIRCUIT AND PARTS ARE SUBJECT TO CHANGE
WITHOUT PRIOR NOTICE.
Summary of Contents for PMA-A100
Page 3: ...3 DIMENSION Ø60 434 20 161 26 394 35 MAX 332 344 70 261 63 ...
Page 5: ...5 Wire arrangement viewed from the bottom Front Panel side Back Panel side ...
Page 15: ...15 BLOCK AND LEVEL DIAGRAM ...
Page 21: ...21 PRINTED WIRING BOARDS 8U 110058 INPUT UNIT 1 2 COMPONENT SIDE ...
Page 22: ...22 8U 110058 INPUT UNIT 2 2 FOIL SIDE ...
Page 23: ...23 8U 110059 uCOM UNIT COMPONENT SIDE FOIL SIDE ...
Page 25: ...25 1U 3709 FLAT AMP UNIT COMPONENT SIDE ...
Page 39: ...39 WIRING DIAGRAM ...
Page 47: ...47 MEMO ...