IDLING ADJUSTMENT
IDLING CURRENT
Setup
1. Lay the unit at an ordinary position away from a direct current from an air condition or fan. Do the adjustment at a
temperature between 15°C (59°F) and 30°C (86°F).
2. Set control as follows.
POWER SWITCH
OFF (
).
VOLUME CONTROL
Fully counterclockwise in the minimum position (
).
(Main Volume and Semifixed resistors [VR501, VR502])
SPEAKER Terminals
Open: do not connect the speakers, dummy load etc.
Adjustment
1. Remove top cover. And then connect DC Voltmeter to test points of 1U-3708-1 (Lch) and 1U-3708-2 (Rch) Power Amp
Printing Wiring Board.
2. Connect power cord to AC wall outlet, and turn POWER switch "ON" (
). Within 10 seconds turn VR501 (Lch) and
VR502 (Rch) clockwise so that the DC Voltmeter reads 12 ±5mV.
3. Then after 2 minutes warmup adjust VR501 and VR502 so that the DC Voltmeter reads 12±5mV.
4. And after 10 minutes warmup adjust VR501 and VR502 so that the DC Voltmeter reads 12±5mV.
DC Voltmeter
Main Volume
1U-3708-2
Power Amp P.W.B. (R)
VR502
1U-3708 -1
Power Amp P.W.B. (L)
VR501
Power
Trans
Power
Trans
Summary of Contents for PMA-A100
Page 3: ...3 DIMENSION Ø60 434 20 161 26 394 35 MAX 332 344 70 261 63 ...
Page 5: ...5 Wire arrangement viewed from the bottom Front Panel side Back Panel side ...
Page 15: ...15 BLOCK AND LEVEL DIAGRAM ...
Page 21: ...21 PRINTED WIRING BOARDS 8U 110058 INPUT UNIT 1 2 COMPONENT SIDE ...
Page 22: ...22 8U 110058 INPUT UNIT 2 2 FOIL SIDE ...
Page 23: ...23 8U 110059 uCOM UNIT COMPONENT SIDE FOIL SIDE ...
Page 25: ...25 1U 3709 FLAT AMP UNIT COMPONENT SIDE ...
Page 39: ...39 WIRING DIAGRAM ...
Page 47: ...47 MEMO ...