12
ENGLISH
Sampler playback
8
SAMPLER
1
Select the source of Sampler
• Turn the ASSIGN switch
y
in the SAMPLER
part to select the desired source.
3
Setting B point / Stop recording
When the B button
o
is pushed during
recording, the B point is set.
• Recording continues for approximately 8
seconds without stopping after set B point.
• If the B point is not set, recording end point
set as B point automatically.
2
Record in Sampler
When the A button
i
is pushed, the sound of
the selected source is recorded to Sampler
memory up to 8 seconds.
• The A button
i
flashes after recording starts.
• When the recording is completed, B button
o
lights up.
5
-1
Select Sampler play mode
You can select play mode for Sampler when
Sampler playback stop.
Loop (default):
Sampler playback continues with looping.
Single:
Sampler playback stops at B point.
Stutter:
Sampler is played while the A button
i
is
pressed and held down.
Loop + Reverse:
Reverse Sampler playback continues with
looping.
Reverse:
Reverse Sampler stops at A point.
S Reverse:
Reverse Sampler is played while the A
button
i
is pressed and held down.
Exit B:
Sampler playback continues over B point
up to recording length.
6
Play Sampler sound
• Playback of the Sampler sound starts when
the A button
i
is pushed after recording has
completed.
• To stop the Sampler sound, push the
MODE/STOP knob
u
.
• When the CROSSFADER ASSIGN switch
!0
in the SAMPLER part is set A or B, you can
perform the Sampler Fader Start by the
Crossfader
!8
. See page 10.
7
Moving Sampler B point
• When the B button
o
is pushed during
Sampler playback, the B point moves to the
point at which the button was pushed, and
Loop playback from point A starts.
4
Setting the Sampler sound level
The sound level (volume) can be set for
Sampler.
• To select “S_Level” turn the MODE/STOP
knob
u
and push.
• Turn the MODE/STOP knob
u
and select
between “–14 dB” and “+6 dB”.
9
Clearing the Sampler data
• While pressing the MODE/STOP knob
u
,
push the A button
i
to clear the Sampler.
Sampler A/B Trim
1
Select A-B Trim mode
• To select “A/BTrim” turn the MODE/STOP
knob
u
and push.
2
Select A point (in A-B Trim)
• Push the A button
i
.
• The A button
i
illumination flashes and Loop
playback starts.
5
Select B point (in A-B Trim)
• Select the A-B Trim mode and push the B
button
o
.
• The B button
o
illumination flashes.
3
Trim A point
• Turn the MODE/STOP knob
u
. You can move
the A point.
4
Save the A point
• Push the MODE/STOP knob
u
to save new
the A point.
6
Trim B point
• Turn the MODE/STOP knob
u
. You can move
the B point.
9
PFL (Pre Fader Level)
1. Press the SPLIT CUE button
@4
.
2. Press the CUE button
!6
that you wish to monitor
1~ 4 (make sure your source is playing).
3. Turn the GAIN control
#5
until the meters peak at
the 0 dB level.
4. Perform your mix using the Crossfader
!8
or Ch.
Fader
!9
at your desire.
NOTES:
• For proper operation, your channel levels should
always be set to or left on reference line 8.
• This adjustment can be made even if the Ch. Fader
is set to zero level.
Setting the Sampler pitch
The sound pitch can be set for Sampler.
• To select “S_Pitch” turn the MODE/STOP
knob
u
and push.
• Turn the MODE/STOP knob
u
and select
between “–100 %” and “+100 %”.
8
To select Loop/Reverse mode, turn the
MODE/STOP knob
u
then push after
recording and before playing.
q
Play mode:
• To select “P_Mode” turn the
MODE/STOP knob
u
and push.
• Turn the MODE/STOP knob
u
and select
“Loop”, “Exit B”, “Single” or “Stutter”.
w
Play direction:
• To select “DirMode” turn the
MODE/STOP knob
u
and push.
• Turn the MODE/STOP knob
u
and select
“Forward” or “Reverse”.
5
-2
10
Monitoring the Sampler data
(SAMPLER CUE)
• When the SAMPLER CUE button
!6
is
pressed, you can check the Sampler data.
NOTE:
When the SAMPLER CUE button is lit, the
Sampler sound is not output into the
Crossfader or MASTER OUT.
7
Save the B point
• Push the MODE/STOP knob
u
to save new
the B point.