background image

2

SC-CX101

Please heed the points listed below during servicing and inspection.

Heed the cautions!

Spots requiring particular attention when servicing, such
as the cabinet, parts, chassis, etc., have cautions indicated
on labels or seals. Be sure to heed these cautions and the
cautions indicated in the handling instructions.

Caution concerning electric shock!

(1) An AC voltage is impressed on this set, so touching in-

ternal metal parts when the set is energized could
cause electric shock. Take care to avoid electric shock,
by for example using an isolating transformer and
gloves when servicing while the set is energized, un-
plugging the power cord when replacing parts, etc.

(2)There are high voltage parts inside. Handle with extra

care when the set is energized.

Caution concerning disassembly and

assembly!

Though great care is taken when manufacturing parts from
sheet metal, there may in some rare cases be burrs on the
edges of parts which could cause injury if fingers are
moved across them. Use gloves to protect your hands.

Only use designated parts!

The set's parts have specific safety properties (fire resis-
tance, voltage resistance, etc.). For replacement parts, be
sure to use parts which have the same properties. In par-
ticular, for the important safety parts that are marked 

z

 on

wiring diagrams and parts lists, be sure to use the desig-
nated parts.

Be sure to mount parts and arrange

the wires as they were originally!

For safety reasons, some parts use tape, tubes or other in-
sulating materials, and some parts are mounted away from
the surface of printed circuit boards. Care is also taken with
the positions of the wires inside and clamps are used to
keep wires away from heating and high voltage parts, so
be sure to set everything back as it was originally.

Inspect for safety after servicing!

Check that all screws, parts and wires removed or discon-
nected for servicing have been put back in their original po-
sitions, inspect that no parts around the area that has been
serviced have been negatively affected, conduct an insu-
lation check on the external metal connectors and between
the blades of the power plug, and otherwise check that
safety is ensured.

(Insulation check procedure)
Unplug the power cord from the power outlet, disconnect
the antenna, plugs, etc., and turn the power switch on. Us-
ing a 500V insulation resistance tester, check that the in-
sulation resistance between the terminals of the power
plug and the externally exposed metal parts (antenna ter-
minal, headphones terminal, microphone terminal, input
terminal, etc.) is 1M

Ω

 or greater. If it is less, the set must

be inspected and repaired.

Concerning important safety

parts

Many of the electric and structural parts used in the set
have special safety properties. In most cases these prop-
erties are difficult to distinguish by sight, and using re-
placement parts with higher ratings (rated power and
withstand voltage) does not necessarily guarantee that
safety performance will be preserved. Parts with safety
properties are indicated as shown below on the wiring dia-
grams and parts lists is this service manual. Be sure to re-
place them with parts with the designated part number.

(1) Schematic diagrams ... Indicated by the 

z

 mark.

(2) Parts lists ... Indicated by the 

z

 mark.

Using parts other than the designated
parts could result in electric shock, fires or
other dangerous situations.

SAFETY PRECAUTIONS

The following check should be performed for the continued protection of the customer and service technician.

LEAKAGE CURRENT CHECK

Before returning the unit to the customer, make sure you make either (1) a leakage current check or (2) a line to chassis
resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the
power cord is less than 460 kohms, the unit is defective.

CAUTION

CAUTION

Summary of Contents for DN-A300M

Page 1: ...m the actual set 注 意 サービスをおこなう前に このサービスマニュアルを 必ずお読みください 本機は 火災 感電 けがなど に対する安全性を確保するために さまざまな配慮を おこなっており また法的には 電気用品安全法 に もとづき 所定の許可を得て製造されております 従ってサービスをおこなう際は これらの安全性が維 持されるよう このサービスマニュアルに記載されて いる注意事項を必ずお守りください 本機の仕様は性能改良のため 予告なく変更すること があります 補修用性能部品の保有期間は 製造打切後 8 年です 修理の際は 必ず取扱説明書を参照の上 作業を行っ てください 本文中に使用しているイラストは 説明の都合上現物 と多少異なる場合があります S 1178 V 03 DE CDM 0803 SERVICE MANUAL SPEAKER SYSTEM MODEL JP...

Page 2: ...ck that all screws parts and wires removed or discon nected for servicing have been put back in their original po sitions inspect that no parts around the area that has been serviced have been negatively affected conduct an insu lation check on the external metal connectors and between the blades of the power plug and otherwise check that safety is ensured Insulation check procedure Unplug the pow...

Page 3: ... 部品の取付けや配線の引きまわしは 元どおりに 安全上 テープやチューブなどの絶縁材料を使用したり プリント基板から浮かして取付けた部品があります また 内部配線は引きまわしやクランパーによって発熱部品や 高圧部品に接近しないように配慮されていますので これ らは必ず元どおりにしてください サービス後は安全点検を サービスのために取り外したねじ 部品 配線などが元ど おりになっているか またサービスした個所の周辺を劣化 させてしまったところがないかなどを点検し 外部金属端 子部と 電源プラグの刃の間の絶縁チェックをおこなうな ど 安全性が確保されていることを確認してください 絶縁チェックの方法 電源コンセントから電源プラグを抜き アンテナやプラグ などを外し 電源スイッチを入れます 500V 絶縁抵抗計 を用いて 電源プラグのそれぞれの端子と外部露出金属部 アンテナ端子 ヘッドホン端子 マ...

Page 4: ...luminum solid 1A 10V G 2 BP Non polar type electrolytic CS Tantalum electrolytic 1C 16V J 5 HR Ripple resistant type CQ Film 1E 25V K 10 DL For change and discharge CK Ceramic 1V 35V M 20 HF For assuring high requency CC Ceramic 1H 50V Z 80 U UL part CP Oil 2A 100V 20 C CSA part CM Mica 2B 125V P 100 W UL CSA type CF Metallized 2C 160V 0 F Lead wire forming CH Metallized 2D 200V C 0 25pF 2E 250V D...

Page 5: ...owing destinations E1C China model JP Japan model EM E2 Europe model E3 U S A Canada model Ref No Part No Part Name Remarks Q ty New 1 00D 949 0062 905 BOX ASSY AA 110 009 01 1 2 00D 949 0063 001 NETWORK ASSY 67 000 177 01 1 3 nsp SCREW 4 4 00D 949 0063 205 SPEAKER WF AA 000 052 01 1 5 00D 949 0063 302 SPEAKER TW AA 000 053 01 1 6 nsp SCREW 10 7 00D 949 0063 409 NET ASSY AA 000 054 01 1 8 00D 949 ...

Page 6: ... CORD SET 62 000 484 01 2 4 nsp POLY BAG 1 5 00D 949 0062 303 FOOT 65 000 267 01 1 6 nsp S S LIST 1 7 00D 949 0062 400 INSTRUCTION MANUAL for JP E1C 87 001 237 01 1 7 949 541 0003 50D INSTRUCTION MANUAL for EM 87 001 324 01 1 8 00D 949 0044 509 POLY BAG 85 000 567 01 1 9 00D 949 0062 507 CUSHION TOP 80 000 694 01 1 10 00D 949 0062 604 CUSHION BOTTOM 80 000 694 11 1 11 00D 949 0062 701 INDIVIDUAL C...

Reviews: