40
ENGLISH
5. CONTROL FEATURES
Mode
Request Code
Status
Finish Mode
“@0?FM”+CR
Stop
“@0FMST”+CR
Next
“@0FMNT”+CR
Recue
“@0FMRC”+CR
Continuous
“@0FMCT”+CR
Power On
“@0?PO”+CR
Play
“@0POPL”+CR
Stop
“@0POST”+CR
Start Mode
“@0?SA”+CR
Play
“@0SAPL”+CR
Cue
“@0SACU”+CR
Stop
“@0SAST”+CR
Cue Mode
“@0?CU”+CR
Recue
“@0CURC”+CR
Next
“@0CUNT”+CR
Auto Cue
“@0?AC”+CR
Off
“@0AC00”+CR
–48dB
“@0AC48”+CR
–42dB
“@0AC42”+CR
–36dB
“@0AC36”+CR
Fade In
“@0?FI”+CR
Time
“@CR
Fade Out
“@0?FO”+CR
Time
“@CR
Skip Back
“@0?SB”+CR
Time
“@CR
End Mon
“@0?EM”+CR
Time
“@0EMXX”+CR
End Of Message
“@0?ED”+CR
Time
“@0EDXX”+CR
Next Tr Reserve
“@0?NR”+CR
On
“@0NR00”+CR
Off
“@0NR01”+CR
Fader Start
“@0?FD”+CR
Play
“@0FDPL”+CR
PlayPause
“@0FDPU”+CR
Index Tally
“@0?IT”+CR
Index2
“@0ITI2”+CR
Index3
“@0ITI3”+CR
Mono
“@0?MO”+CR
On
“@0MO00”+CR
Off
“@0MO01”+CR
PlayList
“@0?PL”+CR
On
“@0PL00”+CR
Off
“@0PL01”+CR
Sleep
“@0?AS”+CR
Time
“@0CR
Eject Lock
“@0?EL”+CR
On
“@0EL00”+CR
Off
“@0EL01”+CR
Digital Out
“@0?DO”+CR
Broadcast
“@0DOBC”+CR
Consumer
“@0DOCS”+CR
Digital FS
“@0?DF”+CR
FS
“@0DFXX”+CR
Machine Name
“@0?MN”+CR
Name
✽
2
“@0MNXXXXXXCR
IP address
“@0?IP”+CR
Address
“@0IPXXXXXXCR
Subnet Mask
“@0?SM”+CR
Mask Bit
“@0SMXXXXXXCR
Gateway
“@0?GW”+CR
Address
“@0GWXXXXXXCR
DNS Address
“@0?DN”+CR
Address
“@0DNXXXXXXCR
Password
“@0?PD”+CR
Password
✽
2
“@0PDXXXXXXCR
✽
2:
0 to 12 digits