Dennard 2040 Installation Manual Download Page 7

a DM Group company

Control Configuration

2040  

Installation Manual

Sheet. 

5

The Dennard 2040 dome can be controlled by one of three methods.

PSU

PSU

drx 100

 +PSU

 

Local 

230Va.c. Input

 

24 Ac

 

Coax Video

 

Coax Video

 

Termination Resistor  Out

 

Termination resistor In

 

RS485

Data link

 

Twisted Pair

 

(20mA) 

  (current loop)

4 x local 

alarms

Video cable

To controller

1 to 16 Dome Cameras

1 to 16 Dome Cameras

Local 

230Va.c.

Input

Video cable

To controller

Local 

24Va.c.

Input

1 to 32 Dome Cameras

RS 485

  Data link

(Daisy chain)

  connect to 

  controller

PSU

Local 

230Va.c.

Input

Up-The-Coax telemetry control 

Commands to control the position of the dome can be

transmitted up the same coax cable used to transmit

the video signal to the recorder station.  Different 

controllers require different protocols and two switches

are provided to select the desired protocol.  

The switches are colour coded, blue and yellow and

located inside the dome camera housing.  To access

them rotate the unit until the switch is available through

the access hole at the top of the case 

(see Fig.6)

.

Configure the switches for the controller being used as

shown in table below.  

The switches are factory set to 253 Den Panel.

Ta

bl

e.

9

Ad

dr

es

s

ch

ar

t

Table.8

Switch settings

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

Yellow

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100 101 102 103 104 105 106 107 108 109 110 111

112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143

144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159

160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175

176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191

192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207

208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223

224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239

240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255

B

L

U

E

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

ADDRESS SWITCHES

Fig.6 Switches

Fig.5 Up the Co-ax

Control

Blue

Yellow Value (see table 9)

Den Panel

F

D

253

Bax AC

F

C

252 

Bax DC

F

E

254

Summary of Contents for 2040

Page 1: ...2040 Dennard support line 44 0 1420 485713 INSTALLATION MANUAL Doc 74 087 ...

Page 2: ...a DM Group company ...

Page 3: ...ation to install the Series 2040 Precision Dome Camera Please refer to the Programming manual for operation and programming features sheet 1 Introduction Index sheet 2 List of contents sheet 3 Tile Mounting sheet 4 Tile Mounting sheet 5 Control Configuration Up the Coax sheet 6 Control Configuration RS485 Serial Connection sheet 7 Control Configuration Twisted Pair sheet 8 Dome Mounting sheet 9 No...

Page 4: ... safety bond 1 x Cardboard Mounting Template N B A power supply unit may have been ordered and delivered separately In addition to the above components the following paperwork is supplied Type 2040 Installation Manual Type 2040 Programming Manual List of contents Components supplied Hole Template Note The top section of the packaging provides a template for marking out mounting holes DO NOT DISCAR...

Page 5: ... panel should be used behind the ceiling tile to distribute the weight to the support frame We recommend that the tile should be removed if possible from the ceiling to simplify the marking and cutting out of mount ing holes Using the Mounting template Fig 1 which is provided as part of the packaging within the box mark out the ceiling hole and centre points for the 3 off 9mm holes Cut and drill t...

Page 6: ... the necessary cables through the hole in the ceiling and connect the 24V ac power coax and optional RS485 cables as shown in table below Reconnect the plug ensuring the correct position see Fig 3 4 Offer up the shell pushing the fixings through the three screw holes Tighten the screws clamping down on the ceiling tile to secure the shell in the ceiling cavity The shell is now ready to accept the ...

Page 7: ... the controller being used as shown in table below The switches are factory set to 253 Den Panel Table 9 Address chart Table 8 Switch settings 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 A B C D E F Yellow 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 ...

Page 8: ... PSU Local 230Va c Input 24 Ac Coax Video Coax Video Termination Resistor Out Termination Resistor In Termination Resistor In Termination resistor In RS485 Data link Twisted Pair 20mA current loop 4 x local alarms Video cable To controller 1 to 16 Dome Cameras 1 to 16 Dome Cameras Local 230Va c Input To controller RS 485 Data link Daisy chain connect to controller PSU Local 230Va c Input PSU Coax ...

Page 9: ...5 Data link Daisy chain connect to controller PSU Local 230Va c Input PSU Coax Video RS485 From the Controller Coax Video Local 230Va c Input PSU Local 230Va c Input Star Card Fig 10 Twisted Pair Twisted Pair Configuration 2040 domes can be operated on 20mA current loop twisted pair cabling by using a DRX100 card and power supply Dennard part num 95066 In this configuration the switches must be se...

Page 10: ...ert the dome camera into the shell ensuring that the safety bond does not become twisted around the case Locate the metal bayonet connector firmly into the top of the shell and rotate the dome clockwise until the unit latches into place Fig 13 To secure the unit in place tighten the single locking small screw on the hemisphere flange If the screw cannot be tightened the dome mechanism may not be p...

Page 11: ...a DM Group company Notes 2040 Installation Manual Sheet 9 ...

Page 12: ...2040 55 Fleet Road Hants GU51 3PN T 44 0 1252 614884 F 44 0 1252 626013 email sales dennard cctv com Doc 74 087 a DM Group company ...

Reviews: