DA Series
Operation Manual
4
Fig. 2.2
Notice: it is not allowable to place any items on the cooler over the metal plate, and the cooler
shall
not
covered to avoid tripping resulting from high temperature of the unit.
3. Installation
Please carefully read this chapter before installation to ensure the proper installation and
reliable operation of the air compressor.
3.1 Environment Requirements
(1)
The air compressor shall be installed indoors where it is well ventilated and lit other than
the places with high dust, high humidity, etchant gas, metallic dust, direct radiation of
sunlight or direct rainwater.;
(2)
The range of ambient temperature is 0
℃
~45
℃
.
(3)
The air compressor shall be kept away from boilers and equipment which may emit heat,
and shall be equipped with awnings with favorable ventilation environment while being
installed outdoors.
(4)
The ventilating fans around and over the air compressor shall set apart at least 900 mm
maintenance space (see Fig. 3.1).
(5)
The altitude shall be less than 1000 m.