![Demiriz Smart 1210 Manual Download Page 11](http://html1.mh-extra.com/html/demiriz/smart-1210/smart-1210_manual_2479871011.webp)
11
Smart 1210
Charging Curve
STEP 1 :
Analysis
analyzes the condition of the battery (charge
level, reverse polarity)
STEP 5 :
Initial Charge
Starts charging with a gentle (soft) charge
STEP 2 :
Recovery
Damaged elements recovery due to an
extended deep discharge algorithm
STEP 6 :
Bulk Charge
Fast charge with maximum current that can
reach 80% charge level.
STEP 3 :
Test
The battery sulphate test monitors the
current characteristics of the battery plates
under constant voltage.
STEP 7 :
Absorption
Charging continues at low current to ensure
safe and effective charging. This limits the
gassing of the battery and is required to
extend the life of the battery.
STEP 4 :
Desulfation
Sulfate removal in battery plates.
STEP 8 :
Floating charge
Maintains battery charge level at its
maximum.
Estimated Charge Time
Battery Capacity
Ah
Slow Mode
4 A
Fast Mode
10 A
5 Ah
1,5 h
Not Suitable !
20 Ah
4 h
Not Suitable !
40 Ah
8 h
Not Suitable !
60 Ah
12 h
5 h
90 Ah
18 h
7 h
120 Ah
24 h
11 h
150 Ah
32 h
15 h