33
?;769
The control unit has an in-built fault diagnostic function display. When a fault occurs, the type of
fault is indicated on LCD with a fault code. See table 2 for the fault codes and meanings,
CODE
DEFINITION
F01
F02
F03
F04
F05
F06
F07
F08
F10
F11
F12
F13
Over Heat Flow
Domestic Hot Water NTC Fault
Central Heating Flow Sensor Fault
Ionization Fault
Flue Sensor Fault
Central Heating Return Sensor Fault
Gas Valve Driving Fault
CH out NTC Sensor Overheat Fault
Central Heating Water Pressure Fault
Circulation Fault
Low Voltage Fault (Voltage<165)
CH Circuit NTC Connection Fault
F01 Overheat Fault: When CH temperature exceeds 98°C, the boiler stops operat-
ing and “RESET” and “F01” indications appears on LCD at the same time. Please
call authorized serviceman.
F02 Domestic Hot Water NTC Fault: When there is a fault on DHW NTC sensor, there
appears F02 fault code on LCD. The boiler still operates and meets domestic hot
water requirement by CH NTC sensors inside the boiler. Please call authorized
serviceman.
F03 Central Heating Flow NTC Sensor Fault: When there is a fault on CH flow NTC
sensor, there appears F03 fault code on LCD. Please call authorized serviceman.
F04 Ionization Fault: When there is gas cut-off, or a fault on ionization electrode, there
appears F04 fault code on LCD due to unsuccessful ignition attempts. Please press
“eco/comfort-reset” button to reset the boiler and ensure that the gas valve is not
closed for any purpose. If the problem still occurs, please call authorized serviceman.
(Table 2)
Summary of Contents for Adonis B24
Page 1: ...Adonis B24 Instruction for Use Duvar Tipi Kombi Wall Hung Combination Boiler 0020146277_01...
Page 2: ......
Page 3: ...Adonis B 24 Duvar Tipi Kombi TR...
Page 22: ...Adonis B 24 Wall Hung Combination Boiler EN...
Page 41: ...Adonis B 24 UA...
Page 58: ...58 1 9S 6 1 9 0 1 19 33...
Page 59: ...59 E8 U Q F...
Page 60: ...Adonis B 24 6 f RU...
Page 78: ...Q 0 0 Q 0 0 0 Q 7 0 4 6 Q 4 O 6 0 78 Q Q R 0 Q...
Page 79: ......