Troubleshooting 

 

 

(Some models may not include all items listed below) 

Symptom Probable 

Cause

Remedy 

No power is being supplied 
to the unit 

1.

 

Trigger Cables connected to the wrong 
place on the machine. 

 

2.

 

Switch on bottom of unit is turned off. 

 

3.

 

Power is not cycling on the machine 
properly. 

 

4.

 

Trigger/Power cable is damaged from 
installation. 

1.

 

Check wiring diagram for proper connection and 
contact dish machine manufacturer for correct 
trigger placement. 

2.

 

Make sure switch is turned on. 

 

3.

 

Check with the dish machine manufacturer if all 
power should have been restored to the unit to see 
if there is an issue with the machine. 

4.

 

Turn power to the dish machine off and inspect the 
cable for any possible damage done. 

Pumps are not priming like 
they should be or not 
holding a prime 

1.

 

Hole in the tubing from the chemical 
container to the pump head. 

 

 

2.

 

Hole in the squeeze tube in the pump 
head. 

3.

 

Fitting is not tight on the tubing 

1.

 

Check the tubing from the chemical container to 
the pump head for leaks by feeling the tubing for 
chemical that has leaked out. Replace the tube if 
necessary. 

2.

 

Replace the squeeze tube after inspecting it for a 
possible hole or leak. 

3.

 

Check both the inlet and outlet fitting and tighten if 
necessary to create a good seal. 

Pump over feeding 

1.

 

If in concentration or probe mode, 
feed rate may not be set correctly. 

2.

 

If in concentration or probe mode, 
probe cable may not be connected 
properly. 

3.

 

If a probe is being used, scale could be 
built up on the probe. 

4.

 

Range of set point is too low. 

1.

 

Check the programming for the feed rate. 

 

2.

 

Check the probe cable connection points and make 
sure it is connected properly. 

 

3.

 

Clean Probe. 

 

4.

 

Check set point in programming. 

Pump under feeding 

1.

 

If in concentration or probe mode, the 
probe cable may be shorted. 

2.

 

If a probe is being used, scale would 
be build up on the probe. 

3.

 

Range of set point is too high. 

1.

 

Check the probe cable for any possible shorts and 
correct the issue where necessary. 

2.

 

Clean Probe. 

 

3.

 

Check set point in programming. 

Rinse/Sanitizer pump not 
running 

1. Speed turned off. 

1. Check the programming to see the speed setting 

and make sure it is on the proper setting. 

 

Warranty  

Merchandise Returns 

No Merchandise will be Returned for Credit Without DEMA’S Written Permission. Returned Merchandise 
Authorization Number is Required in Advance of Return. 

 

Product Warranty 

DEMA products are warranted against defective material and workmanship under normal use and service for 
one year from the date of manufacture.  This limited warranty does not apply to any products that have a 
normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or 
misapplication. Rubber and synthetic rubber parts such as “O”-rings, diaphragms, PVC tubing, and gaskets are 
considered expendable and are not covered under warranty. This warranty is extended only to the original 
buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is 
void. 

Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them 
to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability 
for damages. Return merchandise authorization number must be granted in advance of returned units for repair 
or replacement (See “Merchandise Returns” above). 

Summary of Contents for Nitro Plus

Page 1: ...nsin and a TIVE CLOTHING A Nitro hemical er designed to achine The Nit meet all applic vincial or other lectrical contra certified elect al plumbing co to be installed any other state G AND EYEWEA Plu...

Page 2: ...er Board M Magnetic Field Sensor Packing Kit List Nitro Plus Installation Kit Part Number Description Qty Model NP DL T NP LL T NP DLL T NP LLL T 904 8T Rinse Check Valve Stainless Steel 1 1 1 1 904 8...

Page 3: ...Rinse Sanitizer Pump Rate 0 5oz min 15ml min Operating Temp 4 30 C 40 100 F Case Material ABS Weight 3 8 kg 8 5 lbs Max Altitude 2000 M 6500 ft Environmental Temp 0 40 C 32 104 F Installation Categor...

Page 4: ...which is cle uired and if de eded to go from uired to reach th hine p to install the ty purposes di Nitro Plus Co mmendations OUNDED EA he proper wirin unction with D llowing steps w grammed in th F D...

Page 5: ...wires to the appropriate rinse trigger output between 24 and 480 V 50 60 Hz as recommended by the dish machine manufacturer 3 Make sure to connect the earth ground green wire to the ground connection...

Page 6: ...min Initial Charge 1s 10 min Press Press Press Alarm Delay 5s 10 min Charge Activate Off 60s Charge Clock 5 min 16 hrs Press Initial Charge Activate will determine the length of the rinse trigger tha...

Page 7: ...Charge Clock 5 min 16 hrs Press Initial Charge Activate will determine the length of the rinse trigger that instigates an initial charge while in probe less mode Charge Clock If no triggers are receiv...

Page 8: ...I 1205 Rev B 43816 Page 8 of 13 3 23 2018 Replacement Parts and Reference Information...

Page 9: ...t trigger board to control board 2pcs in kit 11 81 163 1 Power Switch 12 81 18 1 6 x 3 8 Hi Lo Screw for plastic 13 81 181 2 Probe Cable 14 84 176 1 Strain Relief 15 81 19 1 8 Flat Head Screw 16 81 20...

Page 10: ...2 40 41 18 4 1 rewired pow ule joints pre y pickup and d cement Kits Nitro Plus C Detergent P Detergent V Rinse Modu Sanitizer Pu Side Modul er and trigge ewired with c discharge tub Deterg Deterge in...

Page 11: ...1 2 Hole Plug not shown plugs unused 1 2 holes on back of enclosures 9 81 118 15 Detergent Pump Kit Blue Pump Parts Roller Block Assy no motor 10 25 85 19 10 32 x 2 Stainless Steel Screw Rinse Sanitiz...

Page 12: ...e Detergent Silicone 81 177 2 Squeeze Tube Rinse Sani EPDM Default squeeze tube with Nitro Plus 81 177 22 Squeeze Tube Rinse Sani Silicone 81 182 1 1 4 x 1 4 Push On Union JG connects pickup discharge...

Page 13: ...te 2 Check the probe cable connection points and make sure it is connected properly 3 Clean Probe 4 Check set point in programming Pump under feeding 1 If in concentration or probe mode the probe cabl...

Reviews: