background image

 

DEMA® MODEL 693T FOAM STATION II 

INSTALLATION INSTRUCTION 

I-747 

 

 

Page 1 of 8 

Rev. E-40261 

 

 

11/13/14 

 

1.

 

PARTS CHECKLIST: 

 

ITEM DESCRIPTION QTY. 

A.

 

 

Foam Station Assembly 

B.

 

 

¼” ID Tubing & Foot Strainer 

C.

 

 

3/8” ID Tubing & Foot Strainer 

D.

 

 

Ceramic Weight (For ¼” ID Tubing) 

E.

 

 

Ceramic Weight (For 3/8” ID Tubing) 

F.

 

 

Metering Tip Kit 

G.

 

 

#10 Screw & Anchor Kit Set (Total: 4 Screws & 4 Anchors) 

H.

 

 

Label Card 

 

2.

 

INSTALLATION: 

 
 

This product is designed only to be used as described in this instruction sheet.  Adhere to all warnings and 
cautions identified in this document.   

WARNING: 

Installations must conform to all local and national plumbing codes and use 

approved backflow prevention and pressure relief devices where required. 
 

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER 
IS NOT IN USE. 

Always read SDS for all chemicals used and follow personal protective guidelines.

 

 

A.

 

Mounting and Water Supply: 

Locate mounting holes on a permanent vertical wall.  Drill all holes into the drywall using a ¼” diameter bit for use with 
the included #10 screw and anchor set.  (If mounting unit to wood and you do not plan to use the included anchors, drill 
1/8” diameter holes.)  Insert the anchors into drilled holes and hammer them into the wall until they are flush with face 
of wall. Assemble the #10 screws with a phillip screwdriver into the anchors for the keyhole slots so the screw heads are 
sticking out of the wall approximately ½”.  Mount the unit by inserting the screw heads through the keyhole slots and 
tightening the screws.  Secure the unit by inserting screws into the lower 2 holes. 
 
The water inlet is equipped with a female garden hose fitting.  The fitting may be removed to permit direct connection to 
3/8” NPT pipe. 

 Note: Apply pipe dope, hand tighten, and then turn 1-1/2 times with a wrench.

  

DO NOT OVER 

TIGHTEN. 

 

WARNING:  Do not use Teflon tape to seal internal plastic threads as the extra thickness of the tape may cause 
the plastic to crack.  Use non-welding liquid sealant instead. 
 
WARNING:  Water supply should not exceed 125 psi and water temperature must not exceed 150°F. 

 

B.

 

Outlet Connection: 

Connect the discharge hose to the garden hose fitting.  

NOTE: Be sure to clamp garden hose onto wall 

approximately 1 ft. below the unit, (Clamps, screws, & anchors are not supplied.)  

Attach shut-off valve to the 

discharge end of the hose. See Table 1 for hose limitations.

   

 

C.

 

Chemical Supply: 

   

WARNING: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS. 

Place the chemical container in a convenient location not more than six feet below the Foam Station as greater lifts will 
reduce injection capabilities.  The top of the container should not be above the Foam Station.  Cut the vinyl tube to any 
convenient length that will allow the tubing to reach the bottom of the container.  Drop the tubing end with the strainer 

Summary of Contents for 693T FOAM STATION II

Page 1: ...hillip screwdriver into the anchors for the keyhole slots so the screw heads are sticking out of the wall approximately Mount the unit by inserting the screw heads through the keyhole slots and tighte...

Page 2: ...AND LENGTH MIN PRESSURES WATER AIR 25 OF ID 40 PSI 40 PSI 50 OF ID 50 PSI 40 PSI 25 OF ID 60 PSI 40 PSI TABLE 2 Foamer Injection Rate Metering Tip Color Injection Rate for Viscosities Shown 1 cps 75...

Page 3: ...Station permits the operator to select a chemical to foam left hand lever or a chemical to spray right hand lever or a clear water rinse middle lever by opening and closing the appropriate valve with...

Page 4: ...ze See Table 1 7 Air supply is inadequate Increase air pressure by regulating up 8 Detergent is wrong Use a more effective detergent and be sure that product is recommended for foaming 9 Using an oile...

Page 5: ...ge caused by chemicals corrosion improper voltage supply physical abuse or misapplication Rubber and synthetic rubber parts such as O rings diaphragms squeeze tubing and gaskets are considered expenda...

Page 6: ...g 13 93 15 2 Pressure Gauge 14 25 137 12 NPT Nipple X 1 Lg NO PART NO DESCRIPTION 15 16 11 NPT Ball Valve 16 24 11L Foot Strainer For 3 8 ID Tubing 17 24 11MP Foot Strainer For 1 4 ID Tubing 18 61 107...

Page 7: ...2 100 15 Metering Tip Specify Color 3 24 62 SP Metering Knob Kit 4 24 25S O Ring Silicone 5 24 24P Check Valve Ball 6 24 23 2 Check Valve Spring Hasteloy 7 24 37 7 Check Valve Core 8 25 29S O Ring Sil...

Page 8: ...12 23 9 2 Check Valve Spring Hasteloy 13 23 10 Ball 9 32 Dia S S 14 23 11V Check Valve O Ring Viton 15 23 32T Metering Knob NO PART NO DESCRIPTION 16 61 9 Metering Tip Specify Color 17 30 5V 14 O Rin...

Reviews: