background image

 

DEMA BLEND CENTER 

MODELS 633MB, 633MB2 

I-606 

 

 

Pg. 2 of 4 

Rev. B-36300     11/23/10

 

         B.  If unit stops drawing chemical. 

 

 

 

      1.  Is the foot strainer clogged?  Lift from drum and clean. 

 

2.  Is the metering tip blocked?  Remove and clean.   

      3.    Is  the  injector  check  valve  clogged?    Remove  square,             

  plastic metering knob to inspect check valve ball, spring and O-ring. 

         C.  Injector  continues  to  draw  chemical  after  water  valve  closes:  Chemical  supply  is  higher  than  bottom  of  discharge  hose 

 

creating a natural siphon.  Lower the supply vessel or hang up outlet hose after use. 

         D.  Valve Malfunction: 

 

Check that the button moves freely up and down and that a “click” can be heard when the button is pushed and released, 
indicating that the magnet is activating the plunger properly.  Remove cover.  To inspect internal parts, unscrew magnet 
housing and carefully pull off the enclosing tube so as not to drop the plunger, kick-off spring and spacer.  Check for dirt or 
damage impeding plunger and kick-off spring movement.  Inspect the diaphragm, making sure the two small pin holes (bleed 
holes) in the diaphragm convolution are clear to allow the valve to close. 

 

 

TABLE 1 

Tip Color

 

1 cps 

75 cps 

200 cps 

Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio 

Clear 

0.89 143 0.39 326 0.23 553 

Purple 

1.18 109 0.57 225 0.44 293 

Yellow 

1.93  66  1.17 109 0.88 145 

Green 

3.17 40 2.26 57 1.79 72 

Pink 

4.19 31 2.96 43 2.21 58 

Turquoise 

6.51 20 4.77 27 3.63 35 

Black 

7.14 18 5.85 22 4.49 29 

Gray 

9.28 14 7.27 18 5.47 23 

Red 

12.71 10 9.19 14 6.45 20 

Blue 

13.96 9 10.31 12 7.11 18 

Brown 

17.32 7 12.61 10 7.97 16 

White 

20.34 6 14.31 9  8.61 15 

Orange 

21.04 5 15.32 8  8.95 14 

No 

Tip 

23.94 4 17.02 7 10.61 12 

TABLE 2 

Hose I.D.

 

3/8" 1/2" 5/8" 

 

Max. Length 

15 ft. 

50 ft. 

100 ft. 

 

 

RETURNS:

 

NO MERCHANDISE MAY BE RETURNED FOR CREDIT WITHOUT DEMA’S WRITTEN 
PERMISSION.  RETURN MERCHANDISE AUTHORIZATION NUMBER REQUIRED IN 
ADVANCE OF RETURN. 

 
WARRANTY:

 

DEMA products are warranted against defective material and workmanship under normal use and service 
for one year from the date of manufacture.  This limited warranty does not apply to any products which 
have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper 
voltage supply, physical abuse, or misapplication.  Rubber and synthetic rubber parts such as “o”- rings, 
diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty.  
This warranty is extended only to the original buyer of DEMA products.  If products are altered or repaired 
without prior approval of DEMA, this warranty will be void. 

 

 

Defective units or parts should be returned to the factory with transportation prepaid.  If inspection shows 
them to be defective, they will be repaired or replaced without charge, F.O.B. factory.  DEMA assumes no 
liability for damages.  Return merchandise authorization number, to return units for repair or replacement, 
must be granted in advance of return. 

 
 
 
 

Reviews: