background image

• 

Always check whether the site of the installation 

can support the weight of the floodlight. 

  For safety, 1.5 times the weight of the floodlight 

is recommended. If you are unsure do not install.

GENERAL INSTALLATION - SAFETY

1.   Please make sure you are safe when working at height.
2.  Employ the latest safety regulations and procedures to 

ensure the safe installation of this floodlight.

3.  When positioning your floodlight out of doors please 

take note that outdoor electrical installations should 

be installed by a qualified Electrician. Correct circuit 

protection for all exterior electrical services should 

include a residual current device (RCD), also known 

as an earth leakage circuit breaker (ELCB). This simple 

device ensures that the power is cut off immediately; it 

detects a leakage of current to earth, which indicates an 

electrical fault which is potentially threatening to life. 

 

Observe these few Simple rules and keep your outdoor 
electrical installation safe.

INSTALLATION INSTRUCTIONS

1.   Select the required position for the floodlight. 
2.   Remove the mounting bracket from the floodlight.
3.   Fix the mounting bracket to the mounting surface with 

appropriate screws and wall plugs, sufficient to take the 

weight of the fitting. 

4.   Replace the main body of the floodlight to the bracket, 

ensuring that cables are not trapped between the base 

mounting bracket and the floodlight,

5.   Connect the floodlight to the mains supply, with an 

appropriate junction box or connection fitting, making 

sure any exposed connections and joints are sufficiently 

weatherproofed. When using with 110V supply make 

sure the correct CEE plug is fitted to connect to the 

transformer.

6.  Then make the electrical connections as follows:

 

LIVE

 - (Red or Brown) to a terminal marked 

L

 

NEUTRAL

 - (Black or Blue) to a terminal marked 

N

 

EARTH

 - (Green/Yellow) to a terminal marked  

 

WARNING - THIS FITTING MUST BE EARTHED

7.   Ensure that there are no exposed conductors, loose or 

trapped cable strands.

8.   Adjust the angle of the floodlight by the retaining/

adjustment bolt, making sure the bolt is re-tightened.

9.   Switch on the power supply to test.

MAINTENANCE

1.   Please make sure the power is switched off before 

starting any maintenance. 

2.   In order to maintain good even light coverage, the glass 

cover should be cleaned regularly. 

3.  For good heat dissipation the floodlight housing should 

also be cleaned regularly.

4.  Please take care when cleaning the glass or floodlight 

housing. 

 

DO NOT USE water or cleaning solutions, cleaning should 

preferably be done with a clean dry cloth.   

MOUNTING 

BRACKET

MOUNTING BRACKET 

RETAINING/ADJUSTMENT 

BOLT

GUARANTEE

This product is guaranteed in the EU for a period of 5 years from the date of purchase. The guarantee is invalid in the case of improper use, installation, 

tampering, removal of the QC date label, installation in an improper working environment or installation not according to the current edition of the IEE Wiring 

Regulations (BS 7671).  Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the 

faulty unit. Déluce Lighting does not accept responsibility for any installation costs associated with the replacement of this product. Your statutory rights are 

not affected. Déluce Lighting reserves the right to alter specifications without prior notice.

DEL0423b/May_2015[issue_2] Page 2 of 2