ALARM SIGNAL & LED INDICATION

Note : ■■■ represents “beep, beep, beep”

Detector 

Operation

Green

Red

Yellow

Alarmsignal

Power indication

Alarm signal

Fault signal

Normal Operation

Flash once per 

minute ¤

-

-

-

Alarm Condition

-

4 beeps + flash ¤

-

■■■■ -1s -■■■■ -1s 

-■■■■ …

Silence(hush) mode 

under  

alarm condition

-

4 flashes ¤

-

-

Interlink signal 

input(slave)-
CN1231only

-

beep + flash ¤

-

■■■■■■■……….

To activate 

silence(hush) unit 

under interlink 

signal input 

(CN1231 only)

-

Flash ¤

-

-

Pre-alarm warning 

CO level (40 ppm 

or greater level 

detected)

-

Flash once every 

8 seconds until 

alarm ¤

-

-

Memory function- 

indicates the alarm 

has been activated 

before(not from 

test button) due to 

whatever reason

-

-

-

■--8s--■--8s--■

1 beep every 8 

seconds last for 12 

hours. Press button 

once to reset to 

normal mode

Low Battery 

Warning

-

-

1 beep + flash 

every minute ¤

■-1 min-■-

1min-■…….

Sensor Fault

-

-

2 beeps + 

flash every 8 

seconds ¤

■■-8s-■■-8s-■■-

8s-…………

End of sensor 

lifetime warning

-

-

3 Beeps + 

flash every 

minute ¤

■■■-1min-■■■-

1min-■■■……

Temporary delay 

warning signal – 

(Push button to 

temporarily disable 

low battery- or end 

of life- warnings for 

12 hours)

-

Flashes 3 times 

after a push of the 

button

¤ 

(Push button 

again to return to 

warning mode at 

any time)

-

-

Summary of Contents for 36.3533

Page 1: ...o not expose to rain or moisture The detector will not protect against risk of carbon monoxide poisoning when the battery is flat Do cover the alarm when decorating REMEMBER to uncover the unit when d...

Page 2: ...as headaches tightness of chest dizziness fatigue confusion and breathing dif ficulties Because CO poisoning often causes a victim s blood pressure to rise the victim s skin may take on a pink or red...

Page 3: ...screws Connect the battery with ve 2 and ve in the correct position and close the battery cover Hook the alarm on bracket until 3 it locks in place Now test the alarm by pressing in the test button f...

Page 4: ...in 1 5m 5 feet of any gas appliance as furnace In any high level of dusty dirty or greasy area In damp or very humid areas outdoor room or next to bathroom at least installed the alarm 3 meters 10 fee...

Page 5: ...ttempt to repair it yourself warranty will be void Note The test push button is independent function with hush button During the normal testing mode the silence feature will not active ADDITIONAL FEAT...

Page 6: ...r not working prop erly so CO alarm must be replaced End of alarm life warning When the CO alarm comes to end of life the unit will emit 3 beeps with Yellow LED flash every minute When this happen the...

Page 7: ...signal with Red LED flashes every minute This is the signal that the battery needs replacement The alarm works as nor mal during this time Always test the alarm after changing the battery Replace bat...

Page 8: ...ter level detected Flash once every 8 seconds until alarm Memory function indicates the alarm has been activated before not from test button due to whatever reason 8s 8s 1 beep every 8 seconds last fo...

Page 9: ...ed regularly The obligations of this warranty at our discretion shall be limited to the repair or replacement of any part of the alarm and is also conditional on the CO Alarm s not having been tampere...

Reviews: