Deltronic Security 36.3533 Owner'S Manual Download Page 3

INSTALLATION:

CAUTION: DO NOT INSTALL THE ALARM IN NEW OR RENOVATED 
BUILDINGS UNTIL ALL WORK IS COMPLETED, INCLUDING PAINT-

ING AND FINAL CLEANING (EXCESSIVE FUMES FROM PAINTS; SOL

-

VENTS, MAY CAUSE DAMAGE AND DIRT OR DEBRIS MAY BLOCK 
THE GAS ENTRY).

The CO Alarm is designed for easy installation. It comes completely with 
mounting kit. All you have to do is attach the mounting bracket to the wall with 
the fixing screws provided.

Loosen the mounting bracket 

1. 

by pushing it upwards and then 
fasten it onto the ceiling/wall 
with the enclosed screws. 
Connect the battery with + ve 

2. 

and – ve in the correct position 
and close the battery cover. 

Hook the alarm on bracket until 

3. 

it locks in place. Now, test the 
alarm by pressing in the test 

 

button for a few seconds until 

the alarm sounds.

The CO Alarm should be installed by a competent person.

LOCATION – WHERE TO INSTALL CO ALARM

 Minimum Protection 

 Added Protection 

The alarm should be installed in every level of your home, preferably in 

• 

every room. If this is not possible, install at least one alarm near or within 

each separate sleeping area.
If more than one sleeping area or the bedroom doors are closed during the 

• 

night, you may need more than one CO alarm
For added protection, install at least one CO alarm in each level of the 

• 

Summary of Contents for 36.3533

Page 1: ...o not expose to rain or moisture The detector will not protect against risk of carbon monoxide poisoning when the battery is flat Do cover the alarm when decorating REMEMBER to uncover the unit when d...

Page 2: ...as headaches tightness of chest dizziness fatigue confusion and breathing dif ficulties Because CO poisoning often causes a victim s blood pressure to rise the victim s skin may take on a pink or red...

Page 3: ...screws Connect the battery with ve 2 and ve in the correct position and close the battery cover Hook the alarm on bracket until 3 it locks in place Now test the alarm by pressing in the test button f...

Page 4: ...in 1 5m 5 feet of any gas appliance as furnace In any high level of dusty dirty or greasy area In damp or very humid areas outdoor room or next to bathroom at least installed the alarm 3 meters 10 fee...

Page 5: ...ttempt to repair it yourself warranty will be void Note The test push button is independent function with hush button During the normal testing mode the silence feature will not active ADDITIONAL FEAT...

Page 6: ...r not working prop erly so CO alarm must be replaced End of alarm life warning When the CO alarm comes to end of life the unit will emit 3 beeps with Yellow LED flash every minute When this happen the...

Page 7: ...signal with Red LED flashes every minute This is the signal that the battery needs replacement The alarm works as nor mal during this time Always test the alarm after changing the battery Replace bat...

Page 8: ...ter level detected Flash once every 8 seconds until alarm Memory function indicates the alarm has been activated before not from test button due to whatever reason 8s 8s 1 beep every 8 seconds last fo...

Page 9: ...ed regularly The obligations of this warranty at our discretion shall be limited to the repair or replacement of any part of the alarm and is also conditional on the CO Alarm s not having been tampere...

Reviews: