Deltec FR 509 Operating Instructions And Spare Parts Lists Download Page 3

 

Deltec

 

Fluidized Bed Filter FR 509 - FR 1020 

 

Maximum absorption efficiency for Filter media like Deltec AC 
Phosphatadsorber , AC Special Carbon and others is archieved by using Deltec 
a FR filter. Deltec “FR“ Series filter can also be used as a very effective bio 
filter. 
 

Installation 

-

 

FR filters can be installed inside (if space allows) the sump or remote from 
aquarium and filter sump. 

-

 

Connect the FR filter to a pump or bypass of the aquariums filtration 
system. 

-

 

Remove the lid by turning it anticlockwise. 

-

 

Rinse the media thoroughly if not it may cloud the water temporally. 

-

 

Fill in the media; cover the central dawn pipe during the process. 

-

 

DO NOT OVERFILL

 

-

 

Make sure that the sponges are in the correct position and that the Lid O-
Ring is clean and in position. 

-

 

Replace the lid and turn clockwise. 

-

 

Close the tap an the FR filter and switch on the water supply. 

-

 

Open the tap slowly to achieve a steady circulation inside the FR filter. 

 

CHECK FOR ANY LEAKS 

 

General 

The FR filters should ran continuously. When using it in combination with a 
“Kalkwasser” stirrer, ensure that the “Kalkwasser” is not fed directly into the 
FR filter. 
With aquaria containing initially high levels of Phosphate, Rowaphos may have 
to be renewed after a short period of time i.e. If the phosphate level coming 
out of the FR filter is the same as in the aquarium. 

 
Maintenance 

The FR filter should be cleaned thoroughly and if necessary sponges replaced 
every time the media is renewed.  
 

Technical data 

Dimensions (l/w/h) 

appr. 

Filtermaterial 

Water flow rate 

dependently of 

filtermaterial 

FR 509 

180 x 140 x 500 mm 

1,2 Liter 

500 l/h 

FR 512 

280 x 200 x 580 mm 

2,6 Liter 

1500 l/h 

FR 616 

300 x 250 x 600 mm 

4,6 Liter 

2000 l/h 

FR 1016 

300 x 250 x 1000mm 

9,0 Liter 

2000 l/h 

 FR 1020 

350 x 300 x 1000mm 

14,0 Liter 

3000 l/h 

 
 

 

Summary of Contents for FR 509

Page 1: ...eactors Filtri a letto fluido Lit filtrant fluidis Bedienungsanleitungen und Ersatzteillisten Operating instructions and Spare parts lists Istruzioni d uso e parti di ricambio Instructions d emploi et...

Page 2: ...wieder ein und verschlie en den Filter mit dem Filterkopf durch Aufsetzen und Drehen im Uhrzeigersinn Vergewissern Sie sich vorher dass der O Ring frei von Verunreinigungen ist Verbinden Sie den Abspe...

Page 3: ...wise Close the tap an the FR filter and switch on the water supply Open the tap slowly to achieve a steady circulation inside the FR filter CHECK FOR ANY LEAKS General The FR filters should ran contin...

Page 4: ...lo scarico del filtro nel filtro esterno o nell acquario Il deflusso non deve subire strozzature Azionare la pompa impostare il rubinetto di intercettazione in modo che si avverta un leggero ribollir...

Page 5: ...r Replacer l ponge du haut avec la plaque perfor e et fermer le filtre en posant la t te du filtre et en la tournant dans le sens des aiguilles d une montre S assurer auparavant que l anneau torique e...

Page 6: ...FR 509 FR 512 FR 616 FR 1016 FR 1020...

Page 7: ...3041400 93042400 93042400 93043400 O Ring Verschraubung O Ring coupling 7 86003400 XXX XXX XXX XXX Einlass Inlet 8 61752005 XXX XXX XXX XXX Silikonschlauch 10 13 Silikon hose 10 13 9 93420000 XXX XXX...

Page 8: ...O Ring collegamento a vite 7 86003400 XXX XXX XXX XXX Entrata 8 61752005 XXX XXX XXX XXX tubo silicone 10 13 9 93420000 XXX XXX XXX XXX rubinetto 10 XXX 86002600 86002600 86004600 86004600 raccordo t...

Reviews: