Delta VIS100-30G12D Operating Manual Download Page 18

Chapter 3 Basic Operation 

 

VIS100 Vision Sensor Operating Manual 

 

3-9 

3.2.4 Information Page 

 

The Information page contains the following basic information. 

1) 

Version: 

Application version. 

2) 

ID

: Camera identification number. 

3) 

License: 

Application license type. 

4) 

Date: 

Manufacture date (DD/MM/YYYY format). 

 

 

 

3.2.5 Statistics Page 

 

The Statistics page contains the following information. 

1) 

Total Triggered:

 Total number of times the camera is triggered.

 

2) 

Total Read: 

Total number of times the code is read successfully.

 

3) 

Total Unread: 

Total number of times the code isn’t read successfully.

 

4) 

Pass Verification:

 Total number of times for passed verification.

 

5) 

Fail Verification: 

Total number of times for failed verification.

 

6) 

: Resets all statistics to zero.

 

 

 

Summary of Contents for VIS100-30G12D

Page 1: ...Installation 2 2 Chapter 3 Basic Operation 3 1 Application Names and Functions 3 1 3 2 GUI 3 3 3 2 1 Main Page 3 4 3 3 2 Menu Page 3 5 3 3 3 Language 3 8 3 3 4 Information Page 3 9 3 3 5 Statistics Pa...

Page 2: ...s 5 1 Region of Interest ROI 5 1 5 2 Filters 5 2 5 3 Barcode 5 3 5 3 1 1D Barcode 5 3 5 3 2 Data Matrix Code DMC 5 4 5 3 3 QR Code 5 6 5 3 4 Micro QR Code 5 7 5 4 Blob 5 9 Chapter 6 Troubleshooting 6...

Page 3: ...touch the terminals or connect the wires while system power is turned on as this runs the risk of electric shock 3 Please do not disassemble or modify the internal components of the controller 4 Keep...

Page 4: ...kaging and Optional Parts A complete vision system requires the following basic components 1 Vision sensor unit and 0 4 m cable 2 Lens optional first set is included with the 8mm lens 1 1 1 Unit Packa...

Page 5: ...tion 0 3M pixel 640 Horizontal 480 Vertical 90fps Exposure 200 65535 us Lens mount M12 Memory DDR3 512MB 4GB Flash Inspection window Inspection item Code Reader Blob ROI Type Rectangle Circle Pre proc...

Page 6: ...0 681 0 1081 0 1503 0 2241 0 313 195 175 H 131 V 292 0 450 0 597 0 943 0 1315 0 1963 0 273 171 150 H 113 V 244 0 389 0 514 0 806 0 1128 0 1686 0 234 146 140 H 105 V 228 0 362 0 480 0 751 0 1053 0 1575...

Page 7: ...49 9 85 15 145 10 17 2 10 7 10 0 H 7 5 V 13 5 19 8 44 10 77 15 133 10 15 6 9 77 9 0 H 6 75 V 11 6 16 9 39 11 68 15 122 15 14 1 8 79 8 0 H 6 00 V 8 7 13 10 34 13 63 20 111 20 12 5 7 81 7 5 H 5 63 V 8 7...

Page 8: ...nput Output I O Terminal Block Wiring the Sensor Connect and secure the I O Cable to the I O Cable connector located on the bottom of the Vision Sensor The following table lists the I O Cable signal c...

Page 9: ...powered on The grounding wire should be at minimum length using the regulated wire gauge The grounding resistance must be under 100 Please ground the grounding terminal using the third method Do not...

Page 10: ...manufacture date Statistics Displays statistics for the total camera triggered times total code read times total code unread times total pass verification and failed verification times Home Returns t...

Page 11: ...for matching a pre defined pattern Mapping 1 8 Mapping tool for mapping the image with a checkerboard pattern Configuration Functions Icon Name Inspection Tool Camera settings 1 Configures camera imag...

Page 12: ...mode appears according to your license 7 Export settings are available for PC browsers which support HTML5 API BLOB 8 You need a Complete license or Alignment license for this function 3 2 GUI Both Sm...

Page 13: ...nu and Statistics Window width between 1000 px and 1300 px shows the Menu on the left side Window width larger than 1300 px shows the Menu on the left and Statistics on the right of the window 3 2 1 M...

Page 14: ...rd the menu or menu button will show on PC 1 The menu is on the left side of the screen when the browser is in full screen width 2 The menu contains inspection tools that you can use in the process ac...

Page 15: ...ision Sensor Operating Manual 3 6 3 The Configuration page contains all the camera settings Smartphone 1 To access the menu tap the top left button left figure on the screen and the menu right figure...

Page 16: ...7 2 The Application menu contains the inspection tools that you can use to process an image according to your license To activate an application select the check box next to the tool check barcode as...

Page 17: ...3 Language The application supports four languages Simplified Chinese English Japanese Korean PC You change the language by clicking the Language button at the top left of the menu page Smartphone You...

Page 18: ...ure date DD MM YYYY format 3 2 5 Statistics Page The Statistics page contains the following information 1 Total Triggered Total number of times the camera is triggered 2 Total Read Total number of tim...

Page 19: ...e default camera IP address for camera from Inspiraz Technology Name Address IP 192 168 1 10 Mask 255 255 255 0 Gateway 192 168 1 1 DNS 192 168 1 1 4 1 2 Open the Application You must use a web browse...

Page 20: ...ogin page 3 Enter the Username and Password 4 Click Login Default Username admin Default Password admin 4 1 4 Basic Operation Live camera Start Click once to run the live camera Stop Click again or cl...

Page 21: ...ttings to run the camera after rebooting Output Image Outputs the processed image after you open the browser and enter the camera IP Crop Image Auto crops the image using fixed size Auto or a custom s...

Page 22: ...ation There are three types of communication 1 I O Only two output terminals available 2 UDP 3 TCP IP The Communication settings are separated into two parts 1 I O Setting Enabled I O Features Enable...

Page 23: ...C TCP IP Use the TCP client to send the result data support to trigger the camera IP Destination TCP server IP address Port Destination TCP server port number port 4000 for the comm trigger Please use...

Page 24: ...d a new user Username Enter the new username Password Enter the new user password Confirm Password Enter the password again to confirm Delete User Select Delete User to delete a user Note that you can...

Page 25: ...the current user Confirm Password Enter the password again to confirm 4 2 4 Mode The VIS100 application can operate in either Code Reader or Blob mode Use Mode Selection to switch between the 2d code...

Page 26: ...teway address DNS Dynamic name server address MAC Device MAC address 4 2 6 Export Import Settings Set the export settings import settings and export image settings Export settings Click to set the exp...

Page 27: ...h inspection tool has 3 types of ROIs 1 Complete Uses the whole image for the process 2 Rectangle Defines a rectangle ROI that you can rotate and resize 3 Circle Defines a circle ROI that you can rota...

Page 28: ...th various square or circular masks Range Highlights and outlines contour edges Mirror Mirrors an image across its horizontal or vertical axis Rotate Rotates an image by a defined angle Invert Inverts...

Page 29: ...de function to read and decode barcodes You can improve the reading speed by reducing the search area using an ROI and through other settings Number of code Defines the maximum number of codes availab...

Page 30: ...Standard Fastest for finding codes Enhanced More accurate in finding codes but slower than Standard mode Maximum Most accurate in finding codes but slowest compared to other modes Mirror Type Defines...

Page 31: ...k box to compare the decoded barcode with a defined reference For multiple code content add a delimiter between two different results for example 01234567 7654321 The result is OK if the code matches...

Page 32: ...ds in the inspection process Code Length Select the check box to check the length of the decoded barcode The result is OK if the code length matches NG if the code length does not match Code Quality S...

Page 33: ...pixel size of the modules Recognition Mode Standard Fastest for finding codes Enhanced More accurate in finding codes but slower than Standard mode Maximum Most accurate in finding codes but slowest...

Page 34: ...ntent add a delimiter between two different results for example 01234567 7654321 The result is OK if the code matches NG if the code does not match Expert Mode Recognition Mode Standard Fastest for fi...

Page 35: ...scale threshold are marked If too many objects are found use additional conditions to limit the number of detected objects Threshold Finds the gray value between the minimum and maximum pixel values i...

Page 36: ...utside this range Width Filter Select the check box to define the minimum and maximum width size of detected objects The function ignores values outside this range Height Filter Select the check box t...

Page 37: ...tions to resolve the problem Reboot the camera Delete the web browser cache and cookies Go to the Information pages to verify the Version ID License and Date If no information is listed for those valu...

Reviews: