Using wire nuts(not provided), connect house 
power cable to ventilating fan. 

3-5.

 

14 AWG (2.1 mm

2

) is the smallest conductor that 

shall be used for branch-circuit wiring. 

 

4. TEST RUN & GRILLE ATTACHMENT 

4-1.

 

When the power on, check for abnormal 
vibration or sound. 

4-2.

 

Insert the mounting springs into the slots and 
mount the grille to the fan unit. 

Grille

Spring

Slots

 

5. OPERATION 

5-1.

 

Single Speed Model: VFB080C4A1 
Single speed control mode: Turn on the power 
switch to operate ON or OFF, and LED indicator is 
amber. 

5-2.

 

Single Speed Model: VFB050C4A1 
Single speed control mode: Turn on the power 
switch to operate ON or OFF, and LED indicator is 
green. 

 

6. MAINTENANCE   

WARNING: 

Disconnect power source before working on unit. 
Routine maintenance must be done every year.’ 

CAUTION: 

1.

 

Never use gasoline, benzene, thinner or any 
other such chemicals for cleaning the ventilating 
fan. 

2.

 

Do not allow water to enter motor. 

3.

 

Do not soak resin parts in water over 60°C. 

CLEANING

 

1.

 

Open lens cover. Remove the light bulbs 
carefully. Disassemble the lock screw, lock nut 
and light power connections to remove grille.   

2.

 

Wash and clean grille. CAUTION: Do not let water 
into the lamp base. (Use non-abrasive kitchen 
detergent, wipe dry with a new cloth.)   

3.

 

Remove dust and dirt from ventilating fan using 
a vacuum cleaner. 

4.

 

Using a cloth dampened with kitchen detergent, 
remove any dirt from ventilating fan. Wipe dry 
with new cloth. 

5.

 

Replace grille. 

 
 
 
 
 
 
 
 

DIMENSIONS 

8"

1

4

"

5

3
4

"

10

3

4

"

10

3

4

"

 

4" DUCT

1
4

"

3
4

"

1"

10

3
4

"

10

3
4

"

 

 
SPECIFICATIONS 

Model No. 

Voltage

(V) 

Frequency

(Hz) 

Power

(W) 

Air Flow 

@ 0.1SP 

(CFM)  

Weight

(lb.)

Note

VFB080C4A1

 

120 60 7.9  80  5.6 

Single
Speed

VFB050C4A1

 

120 

60 

4.0 50  5.6 

Single
Speed

Note: Design and specifications subject to change without notice. 

 

WARRANTY 

DELTA ELECTRONICS THREE YEAR LIMITED 

WARRANTY

 

 
Delta Electronics Inc.(“Delta Electronics”) warrants 
to the original consumer purchaser in the USA that 
the Breez ventilation fan products will be free from 
defects in material or workmanship. This warranty is 
limited to three (3) years from the original date of 
purchase. 

 

Limitations and Exclusions   

1.

 During the warranty period, a replacement for 

any defective product will be supplied free of 
charge for installation by the consumer. The 
warranty provided herein does not cover charges 
for labor or other costs incurred in the 
troubleshooting, repair, removal, and installation 
service. 

2. All returns of defective parts or products must 

include the product model number, and must be 

    made through an authorized Delta Electronics 

distributor. Authorized returns must be shipped 
prepaid. Repaired or replacement products will 
be shipped by Delta Electronics F.O.B. shipping 
point. 

3. Delta Electronics shall not be liable for any 

indirect, incidental, consequential, punitive, or 
special damages arising out of or in connection 
with products use or performance, regardless of 
the form of action whether in contract, tort 
(including negligence), strict product liability or 
otherwise.  

4. This warranty does not extend to fluorescent 

lamp starters and tubes. 

5. The warranty does not cover if user does not 

comply with manufacture’s installation manual. 

6. To qualify for warranty service, you must notify 

Delta Electronics at the address or telephone 
number below. 

7. Delta Electronics shall have no liability to the 

original owner-user with respect to any defect 
caused by abuse, misuse, neglect, improper 
transportation or storage, improper testing, 
improper installation, improper operation, 
improper use, improper maintenance, improper 
repair, improper alteration, improper 
modification, tampering or accident of products 
or parts thereof, or unusual deterioration or 
degradation of products or parts thereof due to a 
physical environment beyond the requirements 
of products’ specifications. 

 

Address: 4405 Cushing Parkway, Fremont, CA 94538 
US Toll Free Number: 1-888-979-9889