Indoor use
Keep away from
Keep away
Keep away from Do not use a direct
only
light heat source
from fire cooking area
cleaning agent
Layout Considerations
For any Delta
’s indoor air quality monitors, we recommend an area coverage of
160 m
2
with the area of enclosed space calculated individually.
For example:
‧
One open space of
160 m
2
requires one monitor.
‧
Three conference rooms of
80 m
2
each requires three monitors, one in each room.
Space over 160 m
2
should consider installing multiple monitors throughout the room to
achieve optimal coverage. It is also recommended to align the sensor deployment area
with the HVAC thermal zoning plan.
Located at least ~5 meters (16 feet) away from operable windows, doors and diffusers.
【
Installation steps
】
1. Use the wall mount included in the box to install it on the wall, or install in a power
box. The wall mount has screw hole spacing (60mm and 84mm)
2. suitable for power boxes in multiple countries, but the power box must be installed
horizontally as shown in Fig.1.
3. Verify that the power supply and data lines are laid out according to specifications
before installation.
4. As shown in Fig.2, installation the wall mount and verify that all four buckles are
installed and fixed.
5. As shown in Fig.3, use a hexagonal screw driver to fasten the M4 hex socket screws to
complete the installation.
Note
Power source notice
This product uses a
9-24V DC power supply
. AC power must be
converted to the required power source or use the specified power
adapter .
Fig.1
Fig.2
Fig.3
Adapter Requirement