Step 10: Scale and Offset
deltamotion.com
23
Step 10: Scale and Offset
The Scale and Offset parameters convert the Counts, Volts or Current
from the transducer into meaningful measurement units.
First, determine the approximate positions at either end of travel. This
will help you verify later that you performed the procedure correctly.
To set the Scale and Offset:
1.
Go to the
Axes Parameters
pane,
Setup
tab,
Tools and Wizards
section.
2.
Click
Launch
for the Scale/Offset
Wizard in the desired axis.
3.
In the wizard, follow the directions. For help, press the
Help
button.
Tip:
If the wizard does not work for your system, you can manually
determine the Scale and Offset parameters. See the Scaling topic
in the RMCTools help for details.
4.
After completing the wizard, in
the
Axis Parameters
, locate the
Display Units
parameter.
Select the desired display units.
If you wish to use units that are
not listed, choose
Custom
, then
type up to 4 characters in the
Custom Units
parameter.
5.
Click the
Download
button to apply the changes to the RMC.
Remember to save your project and update Flash.
Summary of Contents for RMC200