Step 7: Define the Axes
deltamotion.com
13
Step 7: Define the Axes
To use a physical input or output, it must be assigned to an internal
software axis. The RMC starts with default axis assignments which you
will likely need to change.
Make sure to define the axes at the start of the project. Major changes
to axis definitions later may result in lost axis parameters.
Example Axis Definitions
Position Control Axis
One Control Output, one position input.
Position-Force Control Axis (all part of a single axis)
One Control Output, one position input, dual- input force
Reference Axis
One position input.
Position
Feedback
Dual-input Force Feedback
Valve
Hydraulic Cylinder
Analog
Joystick
Position
Feedback
Control
Output
Position
Feedback
Valve
Hydraulic Cylinder
Control
Output