PJH-36V300WB

www.DeltaPSU.com

REV.00

Instruction Manual

1.    Safety Instructions

2.    Device Description 

       Refer ot Fig .1.:

•    The device is not recommended to be placed on low thermal conductive surface, for example, plastics.

•    For safety reason, please ensure the mounted device is kept at ≥ 8mm safety distance for D1 from other components 

      and equipments. Please insert an insulation sheet between the system and product, if the safety distance is < 8mm for D2 

 

      (Refer to Fig. 2.1)

•    Installation of forced air, to ensure sufficient air flow, always maintain a distance and air flow direction 

     as recommended in Fig. 4. while the device is in operation.

•    Note that the device can become very hot depending on the ambient temperature and load of the power supply.  

     Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!

•    Do not touch the terminals while power is being supplied. Risk of electric shock.

•    Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause:     

     Electric shock; Safety Hazard; Fire; Product failure.

•    For Protection against shock to Class I with PE (protection earth) and Class II with or without FG (functional ground) product, 

 

     the two mounting holes (marked 

 in Fig. 1) need to be connected together to the system’s protective earth or functional ground.        

     Pollution degree and EMC performance with different connections please refer to product datasheet.

•    Warning: The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that  

     the Earth terminal on the connector be connected to the grounded metal surface. 

A

B

C

D

CN1

CN1

CN1

CN1

E

F

CN1

CN1

D2*

D2*

D1

CN1

PSU

Fig. 1. Device Description

Fig. 2. Assembly Reference

Fig. 3. Mounting Orientations

3

1

10

4

1

2

7

D1* ≥ 8mm 

D2* ≥ 30mm 

3.    Installation of the Device

The unit is protected with internal fuse (not replaceable) at L pin and it has been tested and approved on 

20A (UL) and 16A (IEC) branch circuits without additional protection device.

Mounting holes for the power supply.

1)

Mounting holes should be connected to the system’s protective earthing (PE) for Class I or 

fuctional ground (FG) for Class II.

1)

This surface belongs to customer’s end system or panel where the power supply is mounted.

1) Note: 4 × Ø3.5 Mounting Holes; Ø5.5 Max Dimension of Screw Head. Recommended mounting torque for tightening: 4-8Kgf.cm.

Refer to Fig .1.:

Description

PIN 

No.

Function 

► PJH-36V300WBB

Function 

► PJH-36V300WBC

Input connector (CN1)

1

Neutral (N)

Neutral (N)

2

Line (L)

Line (L)

Control and Vsb Connector (CN101)

1

Netutral (N)

Netutral (N)

2

5V

SB

12V

SB

3

GND

GND

4

5V

SB

12V

SB

5

GND

GND

6

Remote On/Off

Remote On/Off

7

GND

GND

8

Power Good

Power Good

9

Remote Sense of V1(-)

Remote Sense of V1(-)

10

Remote Sense of V1(+)

Remote Sense of V1(+)

Output Connector (CN103)

1

GND

GND

Output Connector (CN102)

1

V1(+)

V1(+)

DC voltage adjustment potentiometer

DC OK control LED (Green)

Internal fuse is a time lag type, rated 5A / 250Vac. 