![Delta M10A Quick Installation Manual Download Page 23](http://html1.mh-extra.com/html/delta/m10a/m10a_quick-installation-manual_2472260023.webp)
23
Delta RPI M6A M8A M10A GQIG EU V1 XX 2019-11-08
Standards and guidelines
RPI M6A
RPI M8A
RPI M10A
IP rating
IP65
Safety class
I
Pollution degree
II
Overload behavior
Current limit, power limit
Safety
IEC 62109-1/-2, CE compliance
EMC
EN 61000-6-2, EN 61000-6-3
Noise immunity
IEC 61000-4-2/-3/-4/-5/-6/-8
Harmonic distortion
EN 61000-3-2
EN 61000-3-12
Fluctuations and fibrillations
EN 61000-3-3
EN 61000-3-11
Grid interfaces
see solarsolutions.delta-emea.com
1)
When operating with symmetrical DC inputs (50/50%)
2)
IEC 60664-1, IEC 62109-1
3)
The maximum AC apparent power specifies the maximum power that an inverter is able to supply. This maximum apparent power is not necessarily achieved.
4)
Limited to 4.99 kVA when grid type “AU/NZ PL 4.99k” is selected.
4)
AC voltage and frequency range will be programmed according to the specific country requirements.
Technical Data
EN