19

Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1.0 EN 2022-01-03

V1

K0

K1

K2

K3

K4

K5

K6

CAT5 / CAT6

Ø

 

7,2 / 8,0 / 10,0 mm; 0,25 ... 1,5 mm

2

3

Digital inputs

Pin

Pin

V1

K0

External power-off 

(EPO)

K1

V1 + K1

P

max

 =  0% 

K2

V1 + K1

P

max

 =  30% 

K3

V1 + K1

P

max

 =  60% 

K4

V1 + K1

P

max

 =  100%

K5

Reserved

K6

Reserved

Digital inputs  |  Dry contacts

3

4

A

B

4

Dry contacts

The event at which the relays of the dry contacts trip can 

be set with the Delta Service software.

Summary of Contents for M100A 280

Page 1: ...inverter M100A_280 Delta part number RPI104M280000 product version 0 European Union Graphical Installation Guide Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022...

Page 2: ...nstallers who are trained and approved for installation and com missioning of grid connected solar inverters The information in this manual is to be treated as con fidential and no part of this manual...

Page 3: ...00 1000Vdc MPPT 390 900Vdc MAX Idc 26A 6 MPPT 1000Vdc max MAX Idc 50A 6 MPPT 220 380Vac 230 400Vac 3P4W 3P3W 50 60Hz 83 4A max cos 0 8ind 0 8 cap 50kW 50kVA nom 50kW 55kVA max IP Code IP66 Product ver...

Page 4: ...and DC cables WARNING Electric shock The IP66 protection degree is no longer guaranteed when the door is open Only open the door when absolutely necessary Do not open the door if water or dirt might...

Page 5: ...lightning strikes follow the applicable regulations in your country All external connections must be sufficiently sealed in order to ensure an IP66 protection degree Seal any unused connections with...

Page 6: ...INV I 1x 6 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 1x MOU H INV Q 1x INV X 1x Scope of Delivery Do not use any damaged components...

Page 7: ...Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 Scope of Delivery Amphenol H4 4 6 mm2 DC H4CFC4D MS DC P 16x Amphenol H4 4 6 mm2 DC H4CMC4D MS DC P 16x 6x DC B 2x DC T DC AC AC...

Page 8: ...sories and software Accessories must be ordered separately 2x MOU G Delta Service Software DSS DOWNLOAD partnerportal delta emea com en portal login htm Windows PC RS485 USB Adapter 0 25 1 5 mm2 A Win...

Page 9: ...60 seconds after the power supply is disconnected Before working on the inverter read the supplied manual and follow the instructions provided The housing of the inverter must be grounded if local re...

Page 10: ...10 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 Dimensions 82 82 82 410 82 82 460 11 31 17 27 20 95 25 595 263 4 max 1 8 699 144 5 629 538 7 6 5 mm...

Page 11: ...11 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 Sub 1G 739 80 mm 340 310 130 75 15 12 5 60 60 mm Dimensions...

Page 12: ...300 300 600 200 200 150 12 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 P UV 2020 2021 2022 2023 2024 Installation...

Page 13: ...300 300 200 200 150 200 300 600 830 380 A A 50 300 300 200 A A 13 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 Installation...

Page 14: ...14 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 Wall mounting 8 x 6 5 mm A1 A2 77 kg 8 5 mm 10 Nm 8 5 mm 10 Nm A3 A4 A5 A6...

Page 15: ...15 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 Floor mounting 13 mm 24 5 Nm 13 mm 77 kg B1 B2 B3 B4...

Page 16: ...16 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 SWITCH 1 OFF OFF ON ON SWITCH 2 1 2 3 4 5 6 Mounting...

Page 17: ...17 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 Communication card RS485...

Page 18: ...2 VCC GND DATA DATA DATA DATA RS485 CAT5 CAT6 7 2 8 0 10 0 mm 0 25 1 5 mm2 1 1 RS485 terminal block 2 DIP switch for RS485 termination resistor Switch on the RS485 terminator resistor of the data log...

Page 19: ...T6 7 2 8 0 10 0 mm 0 25 1 5 mm2 3 Digital inputs Pin Pin V1 K0 External power off EPO K1 V1 K1 Pmax 0 K2 V1 K1 Pmax 30 K3 V1 K1 Pmax 60 K4 V1 K1 Pmax 100 K5 Reserved K6 Reserved Digital inputs Dry con...

Page 20: ...ide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 Connect a PC VCC GND DATA DATA DATA DATA RS485 RS485 USB Adapter Delta Service Software DSS Windows PC Connect the PC to the inverte...

Page 21: ...1 57 65 mm 15 Nm 5 5 2 0 mm D4 1 45 57 mm 15 Nm 5 5 0 mm D5 1 33 45 mm 15 20 Nm 4 5 0 mm P AC C1 AC C2 D0 D1 1 D2 1 D2 2 D2 3 D1 2 D1 3 D1 4 AC C2 d mm M Nm P mm D2 1 25 28 mm 15 20 Nm 6 5 2 0 mm D2...

Page 22: ...E Al se Cu Al re rm se 70 240 mm2 70 240 mm2 30 mm L1 L2 L3 N a b c PE a b c M8 24 mm 8 4 mm 12 5 mm M10 40 mm 11 mm 22 mm AC C1 AC PE 22 Graphical Installation Guide M100A_280 RPI104M280000 Product V...

Page 23: ...henol H4 4 6 mm2 DC H4CFC4D MS DC P 16x Amphenol H4 4 6 mm2 DC H4CMC4D MS DC P 16x DC B 1 2 23 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03 Connecting t...

Page 24: ...ct Version 0 EU V1 0 EN 2022 01 03 The inverter must be supplied with alternating current grid and or direct current solar modules Commissioning SWITCH 1 OFF OFF ON ON SWITCH 2 Delta Service Software...

Page 25: ...25 Graphical Installation Guide M100A_280 RPI104M280000 Product Version 0 EU V1 0 EN 2022 01 03...

Page 26: ...nal voltage 5 380 400 480 V 20 30 3 phases PE 3 phases N PE Y Nominal current 160 A Maximum current 168 A at 380 400 V 133 A at 480 V Frequency range 5 50 60 Hz 5 Hz Adjustment range power factor 0 8...

Page 27: ...ad behavior Current limitation power limitation Safety IEC 62109 1 2 CE compliance EMC EN 61000 6 2 6 3 3 11 3 12 Noise immunity IEC 61000 4 2 3 4 5 6 8 Distortion factor EN 61000 3 2 Voltage fluctuat...

Page 28: ...00 9323 toll free Great Britain support uk solar inverter com 0800 051 4281 toll free Greece support greece solar inverter com 49 7641 455 549 Israel supporto israel solar inverter com 800 787 920 tol...