background image

4

Model: 

ITG70LED / VFB070B4LED1

 PREPARATION

Tools Required for Assembly (not included): Hammer, 
Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, 
Phillips Head Screwdriver, Utility Knife
Helpful Tools (not included): Electric Drill, Drill Bits

WARNING: Turn off electricity at breaker box 
before beginning installation.

Carefully remove unit from carton.
Check area above installation location to be sure that 
wiring can run to the planned location and that duct 

work can be run. Make sure the area is sufficient for 

proper ventilation.
Inspect duct work and wiring before proceeding with 
installation.
Before installation, provide inspection and future 
maintenance access at a location that will not 
interfere with installation work.
You may need the help of a second person to install 
this fan: one person on the attic side and one on the 
room side.

Note: Installations may vary depending on how the 
previous bath fan was installed. Supplies necessary 
for the installation of your bath fan are not all included. 
However, most are available at your local home 
improvement or hardware store.

WIRING DIAGRAM

DIMENSION REQUIREMENTS

LIGHT SWITCH

FAN SWITCH

OFF

ON

ON

OFF

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WIRING

PLATE

BLACK
WHITE

GROUND

RED

LIGHT

SWITCH

FAN

SWITCH

WIRE NUT

(NOT INCLUDED)

WIRE NUT

(NOT INCLUDED)

Ceiling 

Opening (L)

Ceiling 

Opening (W)

Ceiling 

Opening (H)

7 1/2 in.

7 1/4 in.

5 3/4 in.

Proper insulation around the fan to minimize building 
heat loss and gain. 4” circular duct is recommended 
for installation. The ducting from this fan to the 
outside of the duilding has a strong effect on the 
air flow, noise and energy use of the fan. Use the 
shortest, straightest duct routing possible for best 
performance, and avoid installing the fan with 
smaller ducts than recommended. Insulation around 
the ducts can reduce energy loss and inhibit mold 
growth. Fans installed with existing ducts may not 

achieve their rated air flow.

 The fan will operate most efficiently when located 
where the shortest possible duct run and minimum 
of elbows will be needed.
Use a roof cap or wall cap that has a built-in damper 
to reduce backdrafts.
External timer can be used please contact Delta 
Breez customer service and consult with a licensed 
electrician for compatibility.

Roof cap

(with built-in

damper)

Seal gap

around 

housing

Caulk termination

to duct

Fan housing

Short piece of flexible

duct helps alignment

and absorbs

sound

or

Wall cap

(with built-in

damper)

Wall cap

(with built-in

damper)

Summary of Contents for ITG70LED

Page 1: ...Package Contents 2 General Safety Information 3 Preparation 4 Assembly Instructions 5 New Construction 5 Existing Construction 6 Grille Installation 8 Operation 8 Care and Maintenance 9 Troubleshootin...

Page 2: ...2 Model ITG70LED VFB070B4LED1 1 2 3 PART DESCRIPTION QTY Fan Body 1 Grille 1 Duct Connector 1 PACKAGE CONTENTS...

Page 3: ...to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society fo...

Page 4: ...ON OFF ON OFF SWITCH purchase separately SWITCH BOX 120 VAC LINE IN WIRING PLATE BLACK WHITE GROUND RED LIGHT SWITCH FAN SWITCH WIRE NUT NOT INCLUDED WIRE NUT NOT INCLUDED Ceiling Opening L Ceiling O...

Page 5: ...or wall stud The fan body should be level and perpendicular to the joist or stud 4 Mount the Fan Body to the joist or stud using nails not included where indicated 5 Pull the wire through the hole and...

Page 6: ...n 2 Measure the opening to ensure it is large enough to accommodate the new Fan Body 7 1 2in x 7 1 4in Note 7 1 4 inch side of opening should be flush with the joist 3 If this fan is not replacing an...

Page 7: ...le and into the junction box not included secure 120VAC house wiring from the wall diagram on page4 14AWG is the smallest conductor that shall be used for branch circuit wiring Push the wires back thr...

Page 8: ...prings on the Grille and insert them into the narrow rectangular slots inside the fan Push the Grille up toward the ceiling Turn on electricity at the breaker box after finishing installation Operatio...

Page 9: ...over 140 Fahrenheit Do not immerse LED module in water Turn off power source Review all safety precautions CARE AND MAINTENANCE 1 To remove grille squeeze springs and pull down 2 Wash and clean the g...

Page 10: ...osing properly If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to...

Page 11: ...SP W Air Flow 0 1 CFM Weight lb LED light spec ITG70LED VFB070B4LED1 120 60 8 0 70 4 8 13 0 Watts 850Lumens 2700K Note Design and specifications subject to change without notice NO Brand Model 1 Lutr...

Page 12: ...s shall not be liable for any indirect incidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in...