1.  Product Instruction 

1-1. General Description 

The  heater  is  designed  for  warming  up  the  air  in  enclosure.  It  can  avoid  equipment 

damaged at lower temperature and water condensation. The heater can be mounted on 

the wall of cabinet. 

 

HEH X1

 

X

 

X - XXX 

(1)

   

(2)

   

(3)

 

(4)    (5) 

 

No 

Item 

Digit 

Specification 

(1) 

Product Message 

HEH 

Heater 

(2) 

Cooling Capacity (W) 

X1 

X1=080 (800W) 

(3) 

Operation Voltage 

AC input 

(4) 

Product Version   

N/A 

(5) 

Customer ID 

N/A 

N/A 

 

 

1-2. Main Feature & Model Number 

Dimensions, Weight & Mounting method 

Dimension (H x W x D) (without flange)   

mm (inch) 

187 x 108 x 79.5 (7.4 x 4.3 x 3.1) 

Application 

 

Indoor 

Weight 

Kg (lbs) 

0.8 (1.8) 

Mounting Method 

 

Door/Side 

Color (optional)   

 

Silver 

Environmental Protection & Performance 

Operating Temperature Range 

°C (°F) 

-30 to +40 (-22 to +104) 

Operating Humidity 

 

Internal: 0~90% RH, non-condensing 

Storage Temperature 

°C (°F) 

-40 to +75 (-40 to +167) 

Storage Relative Humidity 

RH 

Internal: 0~90% RH, non-condensing 

Protection for Dust ,Wind and Water 
(External) 

IEC 60529 

IP20   

Cooling Capacity & Operational Data 

Rated Heating Capacity* 

W   

800   

Rated Heating Current* 

7 (at 115Vac) 

Rated Internal Airflow   

CFM 

35 REF. 

Power & Range 

Input Voltage 

VAC 

115 

Input Voltage Range 

VAC 

104~126 

Inrush Current ** 

21 

Summary of Contents for HEH080AB

Page 1: ...Model No HEH080AB Rev 03 Sample Date Code Sample Issue Date MAY 29 2020 DELTA ELECTRONICS INC 252 SHANG YING ROAD KUEI SAN TEL 886 0 3 3591968 TAOYUAN CITY 333 TAIWAN FAX 886 0 3 3591991 Please send o...

Page 2: ...ion 7 1 1 General Description 7 1 2 Main Feature Model Number 7 1 3 Dimension 9 1 4 Thermal and Airflow 10 2 Electrical Specification 11 2 1 Indicator Connector 11 2 2 Protection 12 3 Environmental Co...

Page 3: ...nstalling heater read these instructions carefully Failure to follow these instructions could damage the product or cause a hazardous condition 2 Check the ratings on the heater label to assure the pr...

Page 4: ...ock Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules 10 This appliance is intended for use only by qualified personnel Caution Do not use these elec...

Page 5: ...ance is not to be used by any persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given proper supervision or instruction 6 Children...

Page 6: ...no HEH080AB Page 6 Specification for Approval Customer Description Heater for Equipment Wall Mounting Customer P N Rev Delta model no HEH080AB Rev 03 Sample revision Date Code Sample issue date MAY 29...

Page 7: ...ight Mounting method Dimension H x W x D without flange mm inch 187 x 108 x 79 5 7 4 x 4 3 x 3 1 Application Indoor Weight Kg lbs 0 8 1 8 Mounting Method Door Side Color optional Silver Environmental...

Page 8: ...A Fans Delta High Efficiency Fan The Heating capacity W is defined as W V A at 0 oC W power consumption V Operating Voltage A Operating current Test condition are AC input 115Vac that is cold start at...

Page 9: ...ct at the bottom and the air outlet at the top as shown 4 The recommended clearances shown by the shadowed area indicates the space that should be kept free for optimum operation of the heater and saf...

Page 10: ...re sensor has been placed in the return air for safe operation Cool air flows into the heater and warmed up by PTC heating element inside of case then supplied to the system Minimum gap for both of co...

Page 11: ...ing point Tolerance 5 C Switching off difference 7 4 C Fuse Cut out temperature 167 C Note DC Fan is powered by adapter AC DC convert The on off temperature by user to setup Startup average current an...

Page 12: ...RH non condensing Ingress Protection Rating IP20 IEC60529 4 Reliability Table Test item Condition High temperature IEC 60068 2 2 Low temperature IEC 60068 2 1 High temp High humidity IEC 60068 2 14 TE...

Page 13: ...ter failure Check the ambient temperature to define heater Is failure or not Please contact Delta or authorized Delta service agent Power on the Fan is stop but the heating is enable at low temp condi...

Page 14: ...ROVED ISSUE DATE ME EE CE 00 ISSUE SPEC VIC PAN 11 06 19 VIC PAN 11 06 19 Ted Tu 11 06 19 Diamond CHEN CW CHEN 11 06 19 11 06 19 01 MODIFY NAME RULE VIC PAN 11 12 19 VIC PAN 11 12 19 Ted Tu 11 12 19 D...