Delta HEH080AB Specification And Manual Download Page 5

Part no.:   

Delta model no.: HEH080AB 

 

 

Page 5   

5. 

This appliance is not to be used by any persons with reduced physical, sensory 

or mental capabilities, or lack of experience and knowledge, unless they have 

been given proper supervision or instruction. 

6. 

Children should be prevented from playing with the appliance. 

 

 

Summary of Contents for HEH080AB

Page 1: ...Model No HEH080AB Rev 03 Sample Date Code Sample Issue Date MAY 29 2020 DELTA ELECTRONICS INC 252 SHANG YING ROAD KUEI SAN TEL 886 0 3 3591968 TAOYUAN CITY 333 TAIWAN FAX 886 0 3 3591991 Please send o...

Page 2: ...ion 7 1 1 General Description 7 1 2 Main Feature Model Number 7 1 3 Dimension 9 1 4 Thermal and Airflow 10 2 Electrical Specification 11 2 1 Indicator Connector 11 2 2 Protection 12 3 Environmental Co...

Page 3: ...nstalling heater read these instructions carefully Failure to follow these instructions could damage the product or cause a hazardous condition 2 Check the ratings on the heater label to assure the pr...

Page 4: ...ock Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules 10 This appliance is intended for use only by qualified personnel Caution Do not use these elec...

Page 5: ...ance is not to be used by any persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given proper supervision or instruction 6 Children...

Page 6: ...no HEH080AB Page 6 Specification for Approval Customer Description Heater for Equipment Wall Mounting Customer P N Rev Delta model no HEH080AB Rev 03 Sample revision Date Code Sample issue date MAY 29...

Page 7: ...ight Mounting method Dimension H x W x D without flange mm inch 187 x 108 x 79 5 7 4 x 4 3 x 3 1 Application Indoor Weight Kg lbs 0 8 1 8 Mounting Method Door Side Color optional Silver Environmental...

Page 8: ...A Fans Delta High Efficiency Fan The Heating capacity W is defined as W V A at 0 oC W power consumption V Operating Voltage A Operating current Test condition are AC input 115Vac that is cold start at...

Page 9: ...ct at the bottom and the air outlet at the top as shown 4 The recommended clearances shown by the shadowed area indicates the space that should be kept free for optimum operation of the heater and saf...

Page 10: ...re sensor has been placed in the return air for safe operation Cool air flows into the heater and warmed up by PTC heating element inside of case then supplied to the system Minimum gap for both of co...

Page 11: ...ing point Tolerance 5 C Switching off difference 7 4 C Fuse Cut out temperature 167 C Note DC Fan is powered by adapter AC DC convert The on off temperature by user to setup Startup average current an...

Page 12: ...RH non condensing Ingress Protection Rating IP20 IEC60529 4 Reliability Table Test item Condition High temperature IEC 60068 2 2 Low temperature IEC 60068 2 1 High temp High humidity IEC 60068 2 14 TE...

Page 13: ...ter failure Check the ambient temperature to define heater Is failure or not Please contact Delta or authorized Delta service agent Power on the Fan is stop but the heating is enable at low temp condi...

Page 14: ...ROVED ISSUE DATE ME EE CE 00 ISSUE SPEC VIC PAN 11 06 19 VIC PAN 11 06 19 Ted Tu 11 06 19 Diamond CHEN CW CHEN 11 06 19 11 06 19 01 MODIFY NAME RULE VIC PAN 11 12 19 VIC PAN 11 12 19 Ted Tu 11 12 19 D...

Reviews: