  Please contact Delta or 

authorized Delta service 
agent. 

Power on, the Fan 
is stop but the 
heating is enable 
at low temp 
condition 

  Fan lock 

  Heater failure 

  Power off product than 

check the Fan blade is no 
block by 
foreign matter 

  Please contact Delta or 

authorized Delta service 
agent. 

Power on, the Fan 
is running but the 
heating is 
disenable at low 
temp condition 

  Over temperature 

protect. 

  Heater failure 

  Check the heater air input 

and output is no block, If 
the heater surface is still 
hot, wait for surface cold 
down and power on again 
at low temp condition for 
check the over protect is 
clear or not. 

  Please contact Delta or 

authorized Delta service 
agent. 

 
 

7.   

Reclaim 

At the end of the unit working life, the produce must not be disposed of as 
urban waste. It must be taken to a special local authority differentiated waste 
collection center or to a dealer providing this service.   

 

 

 

 

 

Summary of Contents for HEH030BB

Page 1: ...EH030BB Rev 01 Sample Date Code Sample Issue Date MAY 29 2020 DELTA ELECTRONICS INC TAOYUAN PLANT TEL 886 0 3 3591968 252 SHANGYING ROAD GUISHAN INDUSTRIAL ZONE FAX 886 0 3 3591991 TAOYUAN CITY 33341 TAIWAN Please send one copy of this specification back after you signed approval for production pre arrangement Approved by Date ...

Page 2: ...uction 7 1 1 General Description 7 1 2 Main Feature Model Number 7 1 3 Dimension 8 1 4 Thermal and Airflow 9 2 Electrical Specification 9 2 1 Indicator Connector 9 2 2 Protection 10 3 Environmental Condition 10 4 Reliability Table 11 5 Safety Certification 11 6 Fault analysis and processing 11 7 Reclaim 12 8 Versions 13 ...

Page 3: ...sure there is no abnormal acoustic noise Safety Notes Before installing heater read these instructions carefully Failure to follow these instructions could damage the product or cause a hazardous condition 2 Check the ratings on the heater label to assure the product is suitable for your application Meaning of WARNING and CAUTION notices Warning To avoid electric shock and equipment damage disconn...

Page 4: ...re must be grounded at the protective ground terminal Use recommended wire and use spring washer to avoid loosening 9 To reduce the risk of electrical shock Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules 10 This appliance is intended for use only by qualified personnel Caution Do not use these electric heaters in dusty dirty corrosive or hazard...

Page 5: ... do not touch exhaust air or surface during operating or just turn off products 5 This appliance is not to be used by any persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given proper supervision or instruction 6 Children should be prevented from playing with the appliance ...

Page 6: ...o HEH030BB Page 6 Specification for Approval Customer Description AC220V 50 60Hz Heater 300W Din Mounting Customer P N Rev Delta model no HEH030BB Rev 01 Sample revision Date Code Sample issue date MAY 29 2020 Quantity 1 pc ...

Page 7: ...Dimension H x W x D without flange mm inch 145 x 75 x 105 5 7 x 3 0 x 4 1 Application Indoor Weight Kg lbs 0 6 1 3 Mounting Method Din rail Color optional BLK Environmental Protection Performance Operating Temperature Range C F 40 to 60 40 to 140 Operating Humidity Internal 0 90 RH non condensing Storage Temperature C F 40 to 75 40 to 167 Storage Relative Humidity RH Internal 0 90 RH non condensin...

Page 8: ... condition are AC input 220Vac that is cold start at ambient temperature 25 o C Please check the notice at section 2 Electrical specification Test condition are AC input 220Vac that is cold start at ambient temperature 20 oC Please check the notice at section 2 Electrical specification 1 3 Dimension NOTE 1 Material PBT 94V0 2 Dimensional tolerance 1 5mm DIN 35mm RAIL MOUNTING CLIP Unit mm inch Mat...

Page 9: ...imum gap for both of cool air inlet and warm air exhaust is required to avoid short circulation 2 Electrical Specification 2 1 Indicator Connector Power Supply Connector Connection Power input JST YLR 02V Pin1 L input Pin2 N input WARNING 1 Do not disconnect and lockup the wire connector while the power is on 2 Ensure the power connector polarity matched accurately to avoid device damage ...

Page 10: ...mum Current 9A Max Duration Time 3sec Measuring methods The PTC element maximum transient current RMS value after power on Inrush current Peak current 50A Max Duration Time 4msec Measuring methods Power on AC input then measure the PEAK current value 2 2 Protection Over Temperature Protection Thermal cut off switcher 85 C heating stop 3 Environmental Condition Operating Temperature 40 to 60 40 to ...

Page 11: ...ated voltage 5 Safety Certification 6 Fault analysis and processing Fault State Analysis of the Reasons Solutions Power on and the Heater is no heating Power failure or no power The target temperature is higher than Thermostat on temp Heater failure Check the power supply and the electric circuit Check the ambient temperature to define heater Is failure or not Please contact Delta or authorized De...

Page 12: ...e heating is disenable at low temp condition Over temperature protect Heater failure Check the heater air input and output is no block If the heater surface is still hot wait for surface cold down and power on again at low temp condition for check the over protect is clear or not Please contact Delta or authorized Delta service agent 7 Reclaim At the end of the unit working life the produce must n...

Page 13: ...WN CHECKED APPROVED ISSUE DATE ME EE CE 00 ISSUE SPEC EDWARD LEE 09 10 18 EDWARD LEE 09 10 18 ARVIN HSU 09 10 18 Diamond CHEN CW CHEN 09 10 18 09 05 18 01 REMOVE Warranty EDWARD LEE 05 29 20 EDWARD LEE 05 29 20 ARVIN HSU 05 29 20 Diamond CHEN GAVIN CHEN 05 29 20 05 29 20 ...

Reviews: