background image

4

7. 

Remove Plastic Electrical Tee Fitting

7.4 

Cleaning Quartz Tube

7.5 

Re-installing Quartz Tube Assembly

8.0 

UV Bulb Removal/Replacement
8. 

Electrical Connector Assembly Removal

8. 

Removing The UV Bulb

8. 

Removing the Bulb Cushion and O-Rings

8.4 

Install Acorn Nut

8.5 

Check For Leaks

9.0 

UV Bulb Installation
9. 

Seating Bulb End Cushion

9. 

Installing O-Rings On Bulb End

9. 

Connecting Bulb Pins To Bulb Connector

9.4 

Inserting Bulb Into Quartz Tube

9.5 

Making Electrical Connection To Bulb

9.6 

Reinstall The Electrical Enclosure Bonnet

9.7 

Plug UV Unit Into Electrical Power

9.8 

Providing Power To EA Unit

0.0  Maintenance – Scheduled Bulb Replacement

0.  Annual Reminder
0.  Disconnect The Power Cord
0.  Remove Electrical Enclosure Bonnet
0.4  Remove The Bulb

.0 

Additional UV Unit Maintenance

.0  Normal Operating Results

.  Ponds
.  Swimming Pools, Fountains, Water Features, Waterfalls

.0  Winterizing

.  Freeze Damage
.  Freezing Weather Precautions

4.0  Swimming Pool Chemicals
5.0  How To Obtain Service
6.0  Parts Schematic and Part Numbers
7.0  Frequently Asked Questions

7.  Salt Water Use
7.  Filter Cleaning
7.  Time Clock Operation
7.4  Residual Effect From UV
7.5  Horizontal Mounting Of UV Unit
7.6  Below Water Installation
7.7  Multiple UV Units For Larger Installations
7.8  GFCI (Ground Fault Circuit Interrupter) Necessity

8.0  Troubleshooting

8.  UV Bulb Will Not Light At Startup
8.  UV Bulb Was Lit, But Is Not Lit Now
8.  UV Bulb Stays Lit When Pump Is Off
8.4  Water Is Green
8.5  GFCI Trips
8.6  Unit Makes Noise When Operating 
8.7  Water Leaks From Electrical Enclosure Bonnet

19.0  Specifications

Summary of Contents for ELEKTRA UV E Series

Page 1: ...ct should be installed by a professional service technician or similar person qualified in electrical equipment installation Improper installation and or operation could cause serious injury property...

Page 2: ...cause blindness DO NOT VIEW UV BULB WHILE OPERATING OR DURING MAINTENANCE 6 The unit must be connected only to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI If this uni...

Page 3: ...ONTENTS 0 0 Forward 1 0 Introduction 2 0 Pre Installation 2 1 Pond Turnover Rates 2 2 Swimming Pool Turnover Rates 3 0 Desired Flow Rate Chart Swimming Pools Fountains Water Features 4 0 Desired Flow...

Page 4: ...Electrical Enclosure Bonnet 10 4 Remove The Bulb 11 0 Additional UV Unit Maintenance 12 0 Normal Operating Results 12 1 Ponds 12 2 Swimming Pools Fountains Water Features Waterfalls 13 0 Winterizing 1...

Page 5: ...important to provide the proper water flow rate through the EUV unit If water passes through the unit too quickly the exposure time of the microorganisms to the UV bulb produced rays will not be suff...

Page 6: ...utlet is outdoors and open to the weather it will need to be an Outdoor type receptacle The EUV unit comes with a eight foot power cord Do not use an extension cord unless it is at least a 16 3 size c...

Page 7: ...he pressure gauge must be installed on one side or the other of the clear tailpiece so that it will be in a vertical position when installed Installing the gauge facing upwardly when the EUV unit is o...

Page 8: ...V unit with the cord connected GFCI installed you may add it in the field You will need to order Part 70 09012 Retrofit Cord Connected GFCI Kit from the supplier of your EUV unit This kit comes comple...

Page 9: ...the circulation pump so that no water is flowing into the EUV unit Once the pump is shut off verify on the pressure gauge that the pressure inside the EUV unit is ZERO If any pressure is indicated on...

Page 10: ...The UV Bulb Seat the quartz tube into the receptor at the bottom of the wet chamber The quartz tube will not go all the way down into the wet chamber unless the rounded end of the quartz tube is seate...

Page 11: ...ic union fitting at the outlet of your EUV unit Your EUV unit is now ready for service 10 0 Scheduled UV Bulb Replacement In addition to cleaning of the quartz tube periodically annual replacement of...

Page 12: ...chlorine odor should disappear in 2 4 days of continual operation after start up on properly sized and installed pools fountains waterfalls and water features Remember as noted before the EUV unit wil...

Page 13: ...a chemical regiment as directed by your pool chemical supplier however you will notice a dramatic decrease in chemical usage as one of the side benefits of the EUV unit is that it attacks the chloram...

Page 14: ...system to allow for larger outputs and flow rates beyond the capacity of a single E 40 or ES 40 unit Delta UV also manufactures a large capacity system the Elektra Max UV system that incorporates fac...

Page 15: ...fault to ground in the electrical circuit or the EUV unit itself 18 3 The UV Bulb Stays Lit When The Pump Is Off The EUV unit is equipped with a safety pressure switch that turns the UV bulb off when...

Page 16: ...given previously remove the quartz tube inspect it for cracks or breakage or for a bad quartz tube seal Re seal the quartz tube d Regardless of where your GFCI is located you can check the UV bulb for...

Page 17: ...cost to the User and will be returned to the User via UPS Surface at the User s expense Delta UV shall be the sole judge in determining the cause of failure of any UV unit Units arriving in broken con...

Page 18: ...___________________ CONTACT ____________________________________________ DATE OF INSTALLATION _________________________________ MODEL _________________ RE LAMP DATE _________________________ RE LAMP D...

Page 19: ...19 NOTES...

Page 20: ...SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS P N 94 35237 Rev 5 08 2008 Delta Ultraviolet Corporation 14936 South Figueroa Street Gardena CA 90248 310 577 1840 PHONE 310 305 9755 FAX CUSTOMERSERVICE DE...

Reviews: