DeviceNet Slave Communication Module DVPDT02-H2
DVP-PLC Operation Manual
25
Attribute
ID
Access
rule
Name
Range
Default
Explanation
Unit: byte
3 Get
Connection
path N/A N/A
Polling path of the parameter
value.
Max. connection path: 255 bytes
4
Get
Descriptor
0 ~ 127
N/A
The descriptor of parameter
5
Get
Data type
1 ~ 8
N/A
The code of data type
6 Get
Data
length
N/A N/A
Number of bytes occupied by the
parameter value (Attribute 1).
Unit: byte
Instance 3: Node address
Attribute
ID
Access
rule
Name
Range
Default
Explanation
1
Get
Parameter value
0 ~ 63
N/A
Node address of DVPDT02-H2
2 Get
Length of
connection path
N/A N/A
The length of connection path
(Attribute 3). “0” refers to the
connection path is not designated.
Unit: byte
3 Get
Connection
path N/A N/A
Polling path of the parameter
value.
Max. connection path: 255 bytes
4
Get
Descriptor
0 ~ 127
N/A
The descriptor of parameter
5
Get
Data type
1 ~ 8
N/A
The code of data type
6 Get
Data
length
N/A N/A
Number of bytes occupied by the
parameter value (Attribute 1).
Unit: byte
Instance 4: Serial transmission speed
Attribute
ID
Access
rule
Name
Range
Default
Explanation
1
Get
Parameter value
0 ~ 2
0
Communication speed of
DVPDT02-H2
2 Get
Length of
connection path
N/A N/A
The length of connection path
(Attribute 3). “0” refers to the
connection path is not designated.
Unit: byte
3 Get
Connection
path N/A N/A
Polling path of the parameter
value.
Max. connection path: 255 bytes
4
Get
Descriptor
0 ~ 127
N/A
The descriptor of parameter
5
Get
Data type
1 ~ 8
N/A
The code of data type
6 Get
Data
length
N/A N/A
Number of bytes occupied by the
parameter value (Attribute 1).
Unit: byte
Instance 5: Length of input I/O data
Attribute
ID
Access
rule
Name
Range
Default
Explanation
1
Get/Set
Parameter value
0 ~ 200
32
Unit: byte